Antitachycardia pacing to terminate ventricular tachyarrhythmia: new insights into how to reduce painful implantable cardioverter defibrillator shocks.

نویسنده

  • Joerg O Schwab
چکیده

This editorial refers to ‘Safety and efficacy of programming a high number of antitachycardia pacing attempts for fast ventricular tachycardia: a prospective study’ by R.P. Martins et al., on page 1457 and ‘First inappropriate implantable cardioverter defibrillator therapy is often due to inaccurate device programming: analysis of the French OPERA registry’ by A. Leenhardt et al., on page 1465

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventricular Fibrillation Terminated by the Seventh Shock

A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...

متن کامل

Antitachycardia pacing for ventricular tachycardia using implantable cardioverter defibrillators:.

Antitachycardia pacing (ATP) refers to the use of pacing stimulation techniques for termination of tachyarrhythmias. Such techniques can be automatically applied using implantable cardioverter defibrillators (ICDs) and offer the potential for painless termination of ventricular tachycardia (VT). Reduction in painful shocks may improve patient quality-of-life (QOL) and extend ICD pulse generator...

متن کامل

Seventh try's a charm: ventricular fibrillation terminated by the seventh shock.

A 49-year-old man consulted our department 3 months after having several implantable cardioverter-defibrillator (ICD) shocks with subsequent syncope. A CRT-D device (Boston Scientific, Cognis 100-D) and a single-element subcutaneous array (Medtronic, model 6996 SQ) had been implanted 2 years previously for primary prevention of sudden cardiac death caused by symptomatic (New York Heart Associat...

متن کامل

Reducing cardioverter-defibrillator shock administration by antitachycardia pacing during device charging.

Programming of antitachycardia pacing in implantable cardioverter-defibrillators (ICDs) has reduced inappropriate device shocks to terminate ventricular arrhythmia. This implies reductions in distress and pain for the patient and prolongs the useful life of the device. Arrhythmia detection and treatment with ICDs can be programmed according to the arrhythmia ventricular rate, discriminating bet...

متن کامل

Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator.

A transvenous implantable cardioverter defibrillator (ICD) was implanted into a 58 year old woman with idiopathic dilated cardiomyopathy who had drug refractory monomorphic ventricular tachycardia (VT). Antitachycardia pacing failed to terminate the VT; termination was attempted at 24 J, which was above the defibrillation threshold. When cardioversion at 24 J was delivered, VT with a different ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 14 10  شماره 

صفحات  -

تاریخ انتشار 2012