Patient weight-based acquisition protocols to optimize (18)F-FDG PET/CT image quality.

نویسندگان

  • Akio Nagaki
  • Masahisa Onoguchi
  • Norikazu Matsutomo
چکیده

UNLABELLED The choice of injected dose of (18)F-FDG and acquisition time is important in obtaining consistently high-quality PET images. The aim of this study was to determine the optimal acquisition protocols based on patient weight for 3-dimensional lutetium oxyorthosilicate PET/CT. METHODS This study was a retrospective analysis of 76 patients ranging from 29 to 101 kg who were injected with 228-395.2 MBq of (18)F-FDG for PET imaging. The study population was divided into 4 weight-based groups: less than 45 kg (group 1), 45-59 kg (group 2), 60-74 kg (group 3), and 75 kg or more (group 4). We measured the true coincidence rate, random coincidence rate, noise-equivalent counting rate (NECR), and random fraction and evaluated image quality by the coefficient of variance (COV) in the largest liver slices. RESULTS The true coincidence rate, random coincidence rate, and NECR significantly increased with increasing injected dose per kilogram (r = 0.91, 0.83, and 0.90; all P < 0.01). NECR maximized at 10.11 MB/kg in underweight patients. The true coincidence rate differed significantly among the 4 groups, except for group 3 versus group 4 (P < 0.01). The ratio of the true coincidence rate for group 2 to groups 3 and 4 was 1.4 and 1.6, respectively. The average random fraction for all 4 groups was approximately 35%. The COV of the 4 groups differed for all pairs (P < 0.01). The COVs in overweight patients were larger than those in underweight patients, and image quality in overweight patients was poor. CONCLUSION We modified acquisition protocols for (18)F-FDG PET/CT according to the characteristics of a 3-dimensional lutetium orthosilicate PET scanner and PET image quality based on patient weight. The optimal acquisition time was approximately 1.4-1.6 times longer in overweight patients than in normal-weight patients. Estimation of optimal acquisition times using the true coincidence rate is more important than other variables in improving PET image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

F -FDG PET/CT Image Quality

The choice of injected dose of 18 F -FDG and acquisition time is important in obtaining consistently high-quality PET images. The aim of this study was to determine the optimal acquisition protocols based on patient weight for 3-dimensional lutetium oxyorthosilicate PET/CT. Methods: This study was a retrospective analysis of 76 patients ranging from 29 to101 kg who were injected with 228–395.2 ...

متن کامل

Optimization of oncological ¹⁸F-FDG PET/CT imaging based on a multiparameter analysis.

PURPOSE This paper describes a method to achieve consistent clinical image quality in (18)F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. METHODS Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variat...

متن کامل

Weight-based, low-dose pediatric whole-body PET/CT protocols.

UNLABELLED Adult PET/CT acquisition protocols need to be modified for pediatric imaging to minimize the radiation dose while maintaining diagnostic utility. We developed pediatric PET/CT acquisition protocols customized to patient weight and estimated the dosimetry and cancer risk of these low-dose protocols to communicate basic imaging risks. METHODS Protocols were developed for whole-body (...

متن کامل

Comparison of imaging protocols for 18F-FDG PET/CT in overweight patients: optimizing scan duration versus administered dose.

UNLABELLED The quality of (18)F-FDG PET/CT images of overweight patients is often degraded. We evaluated the effect of optimizing injected dose or acquisition time on the quality of images of overweight patients using lutetium oxyorthosilicate PET/CT with high-performance detector electronics. METHODS We initially retrospectively measured radioactivity concentrations and signal-to-noise ratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2011