Experimental circumferential canaloplasty with a new Schlemm canal microcatheter.
نویسندگان
چکیده
AIM To present a new, simple, inexpensive Schlemm canal microcatheter for circumferential canaloplasty in a rabbit model. METHODS A rabbit glaucoma animal model was established by intravitreal injection of triamcinolone acetonide. Circumferential canaloplasty with a new Schlemm canal microcatheter (patent license number: 201220029850.0) was performed. The Schlemm canal microcatheter was composed of microcatheter wall and lumen. The wall was made of high refractive index plastic optical fiber that could be attached to an illuminant so that the whole lighted microcatheter was visible during circumferential canaloplasty. The lumen could be attached to an injector for injection of viscoelastic during catheterization. Rabbits were divided randomly into the control, model and treatment groups. Intraocular pressure (IOP) was measured with a Tono-pen tonometer pre-operation and 3, 7, 14, 21 and 28d post-operation. Ultrasound biomicroscopy was performed to visualize the Schlemm canal microcatheter in the Schlemm canal and the sclera pool. RESULTS The Schlemm canal microcatheter could be used to perform circumferential canaloplasty in the rabbit glaucoma animal model. IOP was lower in the treatment group than that in the model group 3, 7, 14 and 28d after operation. There were no significant differences in IOP between the control group and treatment group. The differences among the three groups were statistically significant (3d: F=41.985, P<0.001; 7d: F=65.696, P<0.001; 14d: F=114.599, P<0.001; 28d: F=55.006, P<0.001). CONCLUSION Circumferential canaloplasty is safe and effective in control of experimental glaucoma model in rabbits.
منابع مشابه
Canaloplasty: circumferential viscodilation and tensioning of Schlemm canal using a flexible microcatheter for the treatment of open-angle glaucoma in adults: two-year interim clinical study results.
PURPOSE To evaluate 2-year postsurgical safety and efficacy of canaloplasty (circumferential viscodilation and tensioning of the inner wall of Schlemm canal) to treat open-angle glaucoma (OAG). SETTING Multicenter surgical sites. METHODS This international prospective study comprised adult OAG patients having glaucoma surgery or combined glaucoma-cataract surgery. Qualifying preoperative in...
متن کاملRisk of circumferential viscodilation in viscocanalostomy.
Rękas et al. 1report on a new technique for lavage of predescemetic hemorrhage and blood clot removal after canalostomy assisted using the iTrack microcatheter (Ellex, Inc.). We have been using canaloplasty since 2006. In the beginning we used a 6-0 polypropylene suture for the catheterization of Schlemm canal and placing of a tension suture. This technique was adapted from 360-degree trabeculo...
متن کاملCanaloplastyVA New Approach to Nonpenetrating Glaucoma Surgery
Canaloplasty is a new nonperforating glaucoma operation, which utilizes the experience with viscocanalostomy and adds a further surgical step to keep the ostia open and to stretch the trabecular meshwork permanently. During the operation, a deep sclerectomy and viscocanalostomy are performed as described by Stegmann et al. After this, a 200-2m microcatheter (iTrack; iScience Surgical Corp, Menl...
متن کاملCanaloplasty for primary open-angle glaucoma: long-term outcome.
BACKGROUND/AIMS To study the safety and effectiveness of 360° viscodilation and tensioning of Schlemm canal (canaloplasty) in black African patients with primary open-angle glaucoma (POAG). METHODS Sixty randomly selected eyes of 60 consecutive patients with POAG were included in this prospective study. Canaloplasty comprised 360° catheterisation of Schlemm's canal by means of a flexible micr...
متن کاملCanaloplasty using iTrack 250 Microcatheter with Suture Tensioning on Schlemm's Canal
Open angle glaucoma (OAG) necessitating surgery has traditionally been treated with filtering procedures using antifibrotics. Unfortunately, such filtering procedures are not without the risk of postsurgical complications. Increasing interest in blebless surgery has led to innovative surgical procedures aimed at rejuvenating the natural trabeculo canalicular outflow pathway. Circumferential cat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2018