Quantitative screening for steroids in animal feeding water using reversed phase LC with gradient elution.
نویسندگان
چکیده
Several isocratic separations for the determination of 20 steroids (STER) in animal feeding water samples (AFWS) from drinking-trough by LC using a mobile phase ACN/H(2)O (35:65 v/v) and different RP columns (Hypersil C18, Gemini C18 (GM), Purospher Star C18, Synergi Max C12, and Synergi Fusion) and UV detection were obtained. The elution order was the same: a first group of corticoids (CC) was early eluted, a second group of CC and anabolics (AAS) exhibited intermediate retention, and a third group constituted by AAS was strongly retained. To improve the separation performances of the isocratic separations an ACN gradient elution optimization was carried out for each column. The most satisfactory results were obtained using a Purospher column which allowed the separation of 19 STER in an analysis time close to 26 min. After sample preparation using SPE, method validation was performed in an AFWS spiked with STER according to the EC decision criteria established for quantitative screening methods. For this purpose calibration graphs, extraction efficiencies, decision limits, detection capabilities, precision (repeatability and within-laboratory reproducibility), accuracy, selectivity, and robustness were evaluated. The proposed method was applied to other AFWS with satisfactory results.
منابع مشابه
Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction
A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...
متن کاملStationary Phases for LC Separations at Elevated Temperatures
Please direct correpsondence to Yu Yang at [email protected]. With the advent of column materials that can be used effectively at temperatures well over 100 °C, high temperature liquid chromatography (HTLC) separations have gained more attention in the last few years. Advantages of HTLC include fast analysis time, better selectivity, improved column efficiency, and minimization of the use of o...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملRapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column Authors
An Agilent ZORBAX sub-2 μm Rapid Resolution High Definition (RRHD) 300SB-C8 reversed-phase column was used under optimized chromatographic conditions for delivering highly resolved ultra fast separations of reduced and alkylated monoclonal antibodies. The StableBond C8 phase and RRHD column technology, in combination with robust gradient elution conditions enabled efficient, fast, and effective...
متن کاملAutomated derivatization with o-phthalaldehyde for estimation of amino acids in plasma using reversed-phase high performance liquid chromatography.
A fully automated method for quantitative estimation of plasma amino acids using fluorescence detection of ophthaladehyde/2-mercaptoethanol derivatives of the analytes and their separation by gradient elution reversed-phase HPLC has been described. The method is simple and the three-step gradient elution is suitable for routine analysis of a large number of biological samples due to clear resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of separation science
دوره 31 2 شماره
صفحات -
تاریخ انتشار 2008