SLO power calibration.

نویسندگان

  • R W Nygaard
  • R A Schuchard
چکیده

We present a method for calibrating the Scanning Laser Ophthalmoscope (SLO) that predicts radiant power at any of 256 grayscale values (gsv) and 12 polarized filter (polarizer) levels. Predicted power values, p(gsv), were determined by substitution into polynomials linearly transformed to old or new power at p(0) and p(255). This was compared with observed power values at 125 levels of attenuation/session. Prediction accuracy was the proportion of nonsignificant pairwise comparisons (t-test, p=0.0001). We found that power transformation between polarizers and within sessions has both linear and nonlinear characteristics. Within polarizer and between sessions, however, power transformation has linear characteristics. A 5th-degree polynomial was individually fit, at each polarizer, to session 1 power distributions of 9 gsv steps (0, 31, 63, 95, 127, 159, 191, 223, 255). When adjusted to p(255) and p(0) in new sessions, we obtained p(gsv) that predicted power at 25 gsv * 5 polarizers for 18 days with an accuracy of about 0.84. When only adjusted to p(255), predictive accuracy was 0.81.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SLO radiant power and brightness.

Available output in the Scanning Laser Ophthalmoscope (SLO) may be expressed as radiant power at the beam pivot (SLO exit pupil), in units of microwatts (microW). This power corresponds to dimensions of brightness (like luminance and retinal illuminance) and to a range of related measures (like cd/m2, lm/m2, and the troland value) in both free and Maxwellian views. We demonstrate that the conve...

متن کامل

Clinical investigation of a true color scanning laser ophthalmoscope.

OBJECTIVE To show true color scanning laser ophthalmoscope (SLO) images produced by simultaneously imaging the retina with red, green, and blue lasers. METHODS Low-power red, green, and blue lasers were combined using fiber optics. By rapidly pulsing the lasers, each point on the fundus is illuminated by the 3 colors in quick succession, with the total power level being similar to that from a...

متن کامل

SLO-1-Channels of Parasitic Nematodes Reconstitute Locomotor Behaviour and Emodepside Sensitivity in Caenorhabditis elegans slo-1 Loss of Function Mutants

The calcium-gated potassium channel SLO-1 in Caenorhabditis elegans was recently identified as key component for action of emodepside, a new anthelmintic drug with broad spectrum activity. In this study we identified orthologues of slo-1 in Ancylostoma caninum, Cooperia oncophora, and Haemonchus contortus, all important parasitic nematodes in veterinary medicine. Furthermore, functional analyse...

متن کامل

SLO BK Potassium Channels Couple Gap Junctions to Inhibition of Calcium Signaling in Olfactory Neuron Diversification

The C. elegans AWC olfactory neuron pair communicates to specify asymmetric subtypes AWCOFF and AWCON in a stochastic manner. Intercellular communication between AWC and other neurons in a transient NSY-5 gap junction network antagonizes voltage-activated calcium channels, UNC-2 (CaV2) and EGL-19 (CaV1), in the AWCON cell, but how calcium signaling is downregulated by NSY-5 is only partly under...

متن کامل

13C ENDOR Spectroscopy of Lipoxygenase–Substrate Complexes Reveals the Structural Basis for C–H Activation by Tunneling

In enzymatic C-H activation by hydrogen tunneling, reduced barrier width is important for efficient hydrogen wave function overlap during catalysis. For native enzymes displaying nonadiabatic tunneling, the dominant reactive hydrogen donor-acceptor distance (DAD) is typically ca. 2.7 Å, considerably shorter than normal van der Waals distances. Without a ground state substrate-bound structure fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2001