Evaluation of gravimetric techniques to estimate the microvascular filtration coefficient.

نویسندگان

  • R M Dongaonkar
  • G A Laine
  • R H Stewart
  • C M Quick
چکیده

Microvascular permeability to water is characterized by the microvascular filtration coefficient (K(f)). Conventional gravimetric techniques to estimate K(f) rely on data obtained from either transient or steady-state increases in organ weight in response to increases in microvascular pressure. Both techniques result in considerably different estimates and neither account for interstitial fluid storage and lymphatic return. We therefore developed a theoretical framework to evaluate K(f) estimation techniques by 1) comparing conventional techniques to a novel technique that includes effects of interstitial fluid storage and lymphatic return, 2) evaluating the ability of conventional techniques to reproduce K(f) from simulated gravimetric data generated by a realistic interstitial fluid balance model, 3) analyzing new data collected from rat intestine, and 4) analyzing previously reported data. These approaches revealed that the steady-state gravimetric technique yields estimates that are not directly related to K(f) and are in some cases directly proportional to interstitial compliance. However, the transient gravimetric technique yields accurate estimates in some organs, because the typical experimental duration minimizes the effects of interstitial fluid storage and lymphatic return. Furthermore, our analytical framework reveals that the supposed requirement of tying off all draining lymphatic vessels for the transient technique is unnecessary. Finally, our numerical simulations indicate that our comprehensive technique accurately reproduces the value of K(f) in all organs, is not confounded by interstitial storage and lymphatic return, and provides corroboration of the estimate from the transient technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Invited Review Evaluation of lung injury in rats and mice

Parker, James C., and Mary I. Townsley. Evaluation of lung injury in rats and mice. Am J Physiol Lung Cell Mol Physiol 286: L231–L246, 2004; 10.1152/ ajplung.00049.2003.—Lung injury is a broad descriptor that can be applied to conditions ranging from mild interstitial edema without cellular injury to massive and fatal destruction of the lung. This review addresses those methods that can be read...

متن کامل

Evaluation of lung injury in rats and mice.

Lung injury is a broad descriptor that can be applied to conditions ranging from mild interstitial edema without cellular injury to massive and fatal destruction of the lung. This review addresses those methods that can be readily applied to rats and mice whose small size limits the techniques that can be practically used to assess injury. The methodologies employed range from nonspecific measu...

متن کامل

Optical measurement of isolated canine lung filtration coefficients after alloxan infusion.

In this study, lung filtration coefficient (Kfc) was measured in eight isolated canine lung preparations by using three methods: standard gravimetric (Std), blood-corrected gravimetric (BC), and optical. The lungs were held in zone III conditions and were subjected to an average venous pressure increase of 8.79 +/- 0.93 (mean +/- SD) cmH2O. The permeability of the lungs was increased with an in...

متن کامل

Optical measurement of isolated canine lung filtration coefficients at normal hematocrits.

In this study, lung filtration coefficient (Kfc) values were measured in eight isolated canine lung preparations at normal hematocrit values using three methods: gravimetric, blood-corrected gravimetric, and optical. The lungs were kept in zone 3 conditions and subjected to an average venous pressure increase of 10.24 +/- 0.27 (SE) cmH2O. The resulting Kfc (ml . min-1 . cmH2O-1 . 100 g dry lung...

متن کامل

Capillary filtration in the small intestine of the dog.

The purpose of these studies was to determine the capillary filtration coefficient of the small intestine of anesthetized dogs by the gravimetric technique. Capillary filtration was produced by elevating venous pressure. Filtration rate increased as venous pressure was increased but the relation between the two was not proportional. At venous pressures greater than 10 mm Hg, filtration rate ten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Regulatory, integrative and comparative physiology

دوره 300 6  شماره 

صفحات  -

تاریخ انتشار 2011