Toric implantable collamer lens for high myopic astigmatism in keratoconic patients after six months.
نویسندگان
چکیده
BACKGROUND The aim was to evaluate the safety, efficacy, stability and predictability of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia and myopic astigmatism associated with keratoconus. METHODS The unaided vision and visual acuity, refraction and adverse events were measured in 22 keratoconic eyes of 14 patients after using an implantable collamer lens (ICL) (STAAR Surgical Inc.) to correct refractive error. The outcome was evaluated over six months. RESULTS The mean pre-operative spherical equivalent (SE) and cylinder changed from -4.98 ± 2.63 DS and -2.77 ± 0.99 DC to -0.33 ± 0.51 DS and -1.23 ± 0.65 DC, respectively at the end of six months. Before the surgery the mean Snellen decimal visual acuity was 0.63 ± 0.20. The mean unaided vision and visual acuity changed to 0.76 ± 0.23 and 0.85 ± 0.21, respectively at the end of six months. The mean safety and efficacy indices were 1.40 ± 0.32 and 1.24 ± 0.34, respectively. No eye lost a line of visual acuity and 17 eyes (77.3 per cent) gained one or more lines. Fifteen eyes (68.2 per cent) were within 0.50 D and 20 (90.9 per cent) were within 1.00 D of the desired spherical equivalent refraction. There was a change in manifest refraction of 0.09 ± 0.21 (ranging from -0.25 to +0.75) from one week to six months after the surgery. CONCLUSION The clinical outcomes of the current study demonstrate the safety, efficacy and predictability of toric implantable collamer lens in the correction of myopia and myopic astigmatism associated with keratoconus. The patients' refractions achieved early stability and remained stable during the course of the study.
منابع مشابه
Stability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism
OBJECTIVES To assess the stability of axis and patient satisfaction after toric visian implantable collamer lens (TICL) implantation for moderate to high myopic astigmatism. METHODS Total 33 eyes of 21 consecutive patients who underwent implantation of TICL for the correction of moderate to high myopic astigmatism were recorded and a minimum follow-up of six months was performed. The deviatio...
متن کاملToric phakic implantable collamer lens for correction of astigmatism: 1-year outcomes
PURPOSE The purpose of this study was to assess predictability, efficacy, safety and stability in patients who received a toric implantable collamer lens to correct moderate to high myopic astigmatism. METHODS Forty-three eyes of 23 patients underwent implantation of a toric implantable collamer lens (STAAR Surgical Inc) for astigmatism correction. Mean spherical refraction was -4. 98 ± 3.49 ...
متن کاملVisual Outcomes of Toric Implantable Collamer Lens for Correction of Compound Myopic Astigmatism
Purpose: To assess the visual and refractive outcomes after implantation of Toric Implantable Collamer Lens (T-ICL) in compound myopic astigmatism Methods: In this prospective study, 28 eyes with manifest refraction spherical equivalent (MRSE) errors of -10.94±4.09 diopter (D) and mean cylindrical errors of -3.47±1.39 D underwent T-ICL implantation. Six months after surgery, best corrected and ...
متن کاملPartial Visual Rehabilitation Using a Toric Implantable Collamer Lens in a Patient with Keratoconus: A Case Report with 20 Months of Follow-up
We report the case of a 37-year-old man with a high myopic keratoconus eye that was treated with a posterior chamber toric implantable collamer lens (ICL) in Korea. The patient had a history of contact lens intolerance and did not want to have a corneal transplantation. His uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity were 0.02 and 0.4 in the left eye, respectivel...
متن کاملPosterior Chamber Toric Implantable Collamer Lenses – Literature Review
Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical & experimental optometry
دوره 96 2 شماره
صفحات -
تاریخ انتشار 2013