Fractured retained ureteral stent in a patient lost to follow-up.
نویسندگان
چکیده
Retained ureteral stents in patients lost to follow-up present a challenge to urologists. Patients may present with recurrent flank pain, pyelonephritis, stent migration or encrustation, and ureteral obstruction, with resultant renal failure. Rarely, a long-indwelling period may result in stent fragmentation. Herein, we present a case of a fractured retained ureteral stent noted in a patient lost to follow-up for five years and resurfaced only after complaints of contralateral renal colic.
منابع مشابه
برگشت کامل عملکرد کلیه پیوندی 2 ماه پس از برداشتن استنت اورتر(گزارش 1 مورد)
Urological complications after kidney transplantation(Tx) have been reported by many transplant centers. Most of surgical teams have planned for ureteral stent to prevent these urological complications especially urinary tract obstruction. In this report we present a 40-year-old woman who received a kidney allograft from a living unrelated donor(LURD) in May 1999. Because of disus...
متن کاملA new patient safety smartphone application for prevention of “forgotten” ureteral stents: results from a clinical pilot study in 194 patients
BACKGROUND Approximately 12% of all ureteral stents placed are retained or "forgotten." Forgotten stents are associated with significant safety concerns as well as increased costs and legal issues. Retained ureteral stents (RUS) often occur due to lack of clinical follow-up, communication or language barriers, and economic concerns. METHODS We describe a multiplatform application that facilit...
متن کاملCombined endoscopic surgery in the prone-split leg position for successful single-session removal of an encrusted ureteral stent: a case report
INTRODUCTION Although encrusted stents may lead to some unwanted complications including urinary tract obstruction, urinary sepsis, and potential loss of kidney function, there is currently no consensus on the most efficient method for managing stents that are intentionally left in situ. This is the first report describing the management of an encrusted stent using combined endoscopic surgery i...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملAn Indwelling Ureteral Stent Forgotten for Over 12 Years
Ureteral stents are one of the most commonly used urologic devices with the purpose of establishing and maintaining ureteral patency. They are also associated with a number of complications including infection, migration, stent-related symptoms, and encrustation, leading to lithiasis. Prolonged stent dwell time is associated with a greater degree of these complications. We present the case of a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endourology
دوره 25 12 شماره
صفحات -
تاریخ انتشار 2011