Resonance-enhanced laser-induced plasma spectroscopy for sensitive elemental analysis: Elucidation of enhancement mechanisms

نویسندگان

  • S. L. Lui
  • N. H. Cheung
چکیده

When performing laser-induced plasma spectroscopy for elemental analysis, the analyte signal-to-noise ratio increased from four to over fifty if the plume was reheated by a dye laser pulse tuned to resonant absorption. Time-resolved studies showed that the enhancement was not due to resonance photoionization. Rather, efficient and controlled rekindling of a larger plume volume was the key mechanism. The signal-to-noise ratio further increased to over a hundred if the atmosphere was replaced by a low-pressure heavy inert gas. The ambient gas helped confine and thermally insulate the expanding vapor. © 2002 American Institute of Physics. @DOI: 10.1063/1.1532774#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biosensing Based on Surface-Enhanced Raman Spectroscopy by Using Metal Nanoparticles

Surface-enhanced Raman spectroscopy (SERS) is a promising tool in the analytical science because it provides good selectivity and sensitivity without the labeling process required by fluorescence detection. This technique consists of locating the target analyte on nanometer range of roughed Au-nanoparticles. The presence of the metal nanoparticles provides a tremendous enhancement to the result...

متن کامل

Elemental analysis by microwave-assisted laser-induced breakdown spectroscopy: Evaluation on ceramics

A new Laser-Induced Breakdown Spectroscopy (LIBS) enhancement method utilizing interaction between microwave radiation and laser-induced plasma has been evaluated. Experimental parameters such as laser pulse irradiance, microwave duration, and surrounding gas were studied and optimized for the microwave effect through a series of experiments on a piece of alumina ceramic sample. Up to 33 times ...

متن کامل

Analysis of solids by laser ablation and resonance-enhanced laser-induced plasma spectroscopy

An analytical technique based on resonance-enhanced laser-induced plasma spectroscopy was demonstrated. Pellets of potassium iodate containing trace amounts of sodium were ablated by a 532-nm laser pulse in air. After 30 ns, the plasma plume was intercepted by a 404.4-nm laser pulse to resonantly photoionize the potassium atoms in the vapor plume. The 589-nm emissions of the sodium were found t...

متن کامل

Role of laser pre-pulse wavelength and inter-pulse delay on signal enhancement in collinear double-pulse laser-induced breakdown spectroscopy

a r t i c l e i n f o Keywords: LIBS Double pulse LIBS Plasma diagnostics LPP Dual-pulse (DP) laser-induced breakdown spectroscopy (LIBS) provides significant improvement in signal intensity as compared to conventional single-pulse LIBS. We investigated collinear DPLIBS experimental performance using various laser wavelength combinations employing 1064 nm, 532 nm, and 266 nm Nd:YAG lasers. In p...

متن کامل

Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was develop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002