A Stability Indicating Rp-hplc Method for Simultaneous Determination of Halobetasol Propionate and P-chlorocresol in Creams
نویسنده
چکیده
A simple, selective, accurate high performance liquid chromatographic method was developed and validated for an analysis of Halobetasol Propionate and p-Chlorocresol in pharmaceutical formulations. Chromatographic separation achieved by gradient programme on a C18 column (Waters Novapak C-18, 250 x 4.6mm, 4μm column) utilizing a mobile phases of A (pH 2.5 phosphate buffer) and B (mixture of buffer, acetonitrile and methanol in the ratio of 20:70:10, v/v/v respectively) at a flow rate of 1.0 ml/min with UV detection at 240nm. The retention time of Halobetasol Propionate and p-Chlorocresol were6.3 and 8.9 min, respectively. The total run time is 15 minutes. The developed method was validated in terms of accuracy, precision, linearity, specificity, robustness and solution stability.This study aimed at developing and validating an HPLC method, being simple, accurate and selective and the proposed method can be used for the estimation of these two components in pharmaceutical preparations.
منابع مشابه
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملImpurity profiling and a stability-indicating UPLC method development and validation for the estimation of related impurities of halobetasol propionate in halobetasol propionate 0.05% (w/w) cream.
A simple, short and stability-indicating reverse phase-ultra-performance liquid chromatography method was developed and validated for the quantitative determination of related impurities of halobetasol propionate in halobetasol propionate 0.05% cream formulation. The proposed method was developed on an ACQUITY UPLC™ BEH Phenyl (2.1 × 100 mm, 1.7 µm) column at 40°C with a mobile phase containing...
متن کامل