Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers

نویسندگان

  • Joanna Kowalska
  • Małgorzata Szewczyńska
  • Małgorzata Pośniak
چکیده

Office devices can release volatile organic compounds (VOCs) partly generated by toners and inks, as well as particles of paper. The aim of the presented study is to identify indoor emissions of volatile halogenated organic compounds into the office workspace environment. Mixtures of organic pollutants emitted by seven office devices, i.e. printers and copiers, were analyzed by taking samples in laboratory conditions during the operation of these appliances. Tests of volatile organic compound emissions from selected office devices were conducted in a simulated environment (test chamber). Samples of VOCs were collected using three-layered thermal desorption tubes. Separation and identification of organic pollutant emissions were made using thermal desorption combined with gas chromatography coupled to mass spectrometry. Test chamber studies indicated that operation of the office printer and copier would contribute to the significant concentration level of VOCs in typical office indoor air. Among the determined volatile halogenated compounds, only chlorinated organic compounds were identified, inter alia: trichloroethylene - carcinogenic - and tetrachloroethylene - possibly carcinogenic to human. The results show that daily exposure of an office worker to chemical factors released by the tested printing and copying units can be variable in terms of concentrations of VOCs. The highest emissions in the test chamber during printing were measured for ethylbenzene up to 41.3 μg m(-3), xylenes up to 40.5 μg m(-3) and in case of halogenated compounds the highest concentration for chlorobenzene was 6.48 μg m(-3). The study included the comparison of chamber concentrations and unit-specific emission rates of selected VOCs and the identified halogenated compounds. The highest amount of total VOCs was emitted while copying with device D and was rated above 1235 μg m(-3) and 8400 μg unit(-1) h(-1) on average.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantifying Pollutant Emissions from Office Equipment: a Concern in Energy-efficient Buildings

This study addresses emissions from office equipment with a literature review and measurements from two phases of controlled chamber experiments. Phase I experiments screened for the types of pollutants emitted from five classes of computers and printers placed in a 20 cubic meter stainless steel chamber. Phase II experiments measured volatile organic compounds, low‐molecular‐weight aldehydes, ...

متن کامل

[The study of polycyclic aromatic hydrocarbons in particulate fractions emitted by office printers and copiers].

BACKGROUND This article presents the study ofpolycyclic aromatic hydrocarbons (PAHs) adsorbed on fine particles emitted during the simulated operation of office printers and copiers. MATERIAL AND METHODS In the study three types of printers, and four types of office copiers were used. Measurements were carried out in a closed measuring chamber. Air samples (fractions of particulate matter, PM...

متن کامل

A comment on 'Theegarten et al.: Submesothelial deposition of carbon nanoparticles after toner exposition: Case report. Diagnostic Pathology 2010, 5:77'

A comment on ‘Theegarten et al.: Submesothelial deposition of carbon nanoparticles after toner exposition: Case report. Diagnostic Pathology 2010, 5:77’ We read with interest the article by Theegarten et al. [1] which reports on the case of a patient in whose peritoneum were found submesothial aggregates of carbon nanoparticles (CNPs) with a diameter of 31-67 nm. From their literature study and...

متن کامل

RADIO FREQUENCY NOISE MEASUREMENTS AND MODELS FOR INDOOll

This paper describes . average and impulsive noise measurements inside several office buildings and retail stores. The receiver had a 70-dB dynamic range and operated at 918 MHz, 2.44 GHz, and 4.0 GHz with a nominal 40 MHz 3-dB RF bandwidth. Omni-directional and directional antennas were used to investigate the characteristics and sources of RF noise in indoor channels. Statistical analyseSof -...

متن کامل

A measurement on chemicals emitted from computers and printers using test chamber method

The printers emit the chemical compound when its temperature rises during normal operations. And it primarily influenced the chemical concentrations such as formaldehyde and VOCs (Volatile Organic Compounds) in a living space. The measurements on the various types of prints from different manufacturers such as laser jet type, inkjet type were performed in emission test chambers of 1m3 and 5m3 w...