Vibration analysis of obturator prostheses with different bulb height designs.

نویسندگان

  • Makio Kobayashi
  • Meiko Oki
  • Shogo Ozawa
  • Takaaki Inoue
  • Hitoshi Mukohyama
  • Tsuyoshi Takato
  • Takashi Ohyama
  • Hisashi Taniguchi
چکیده

The purpose of this study was to investigate the effect on the vibratory characteristics of a cast hollow obturator prosthesis retainer when varying its bulb height. Bulb parts with high (H), middle (M), and low (L) lateral walls were prepared. A Vibration Generator was used to excite the three obturators, while a Laser-Doppler Vibrometer was employed to detect the vibrations at specified measurement points. The frequency response functions of each obturator were recorded on an FFT analyzer to enable their modal shapes to be identified. In addition, transient response simulations were carried out and the decay rate (DR) and the maximum amplitude (MA) of the rest and clasp parts of each obturator were obtained. These were statistically analyzed by ANOVA and Fisher's PLSD test (p < 0.01). The modal shapes were almost the same in all obturators. Significant differences were found in DR in all pairs among the three obturator prostheses, with the DR of the L type being the highest. On the other hand, there were no significant differences in MA. We conclude that the L type is preferable from the standpoint of its vibratory characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The vibratory characteristics of obturators with different bulb height and form designs.

The aim of the present study was to investigate whether the vibratory characteristics of obturator prostheses are affected by bulb design, i.e.: the hollow or buccal flange type, and different lateral and medial bulb heights. Buccal flange and hollow bulb obturator prostheses were fabricated with two different lateral bulb wall heights and two different medial bulb wall heights. Ultimately, eig...

متن کامل

Double Investment Technique of Hollow Bulb Denture Obturator Fabrication in a Completely Edentulous Patient

Introduction: Prosthodontic management of palatal defects has been employed for many years. Palatal defects of any extent cause multiple problems in speech, mastication and aesthetics. Obturator prosthesis for an edentulous patient is more critical in terms of its movements as there is no mechanical retention available. Obturators and facial prostheses are important not only for rehabilitation ...

متن کامل

Efficacy of speech aid prostheses for acquired defects of the soft palate and velopharyngeal inadequacy--clinical assessments and cephalometric analysis: a Memorial Sloan-Kettering Study.

BACKGROUND Restoration of speech after surgical resection for oropharyngeal cancer traditionally includes maxillofacial prosthetic intervention. Relatively few publications with objective speech outcomes exist. The purpose of this study was to evaluate speech outcome relative to the size of the surgical defect, the type of speech prosthesis, and the height and position of the speech bulb in rel...

متن کامل

The Hollow Bulb Obturator Fabrication, Where do We Stand in 2017

Maxillectomy defects can result in oroantral communication that may lead to difficulty in swallowing, deglutition, impaired speech, and not to mention the resultant facial disfigurement. The prosthodontist in addition to the surgeon of course, plays a significant role in restoration and rehabilitation of such defects, as good functional results have been reported for patients provided with obtu...

متن کامل

Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

BACKGROUND The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). MATERIAL AND METHODS A 3-dimensional finite element model of an Aramany class IV defect was created. Three diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical and dental sciences

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 2002