A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error.
نویسندگان
چکیده
The International Commission on Radiation Units and Measurements Report 62 (ICRU 1999) introduced the concept of expanding the clinical target volume (CTV) to form the planning target volume by a two-step process. The first step is adding a clinically definable internal margin, which produces an internal target volume that accounts for the size, shape and position of the CTV in relation to anatomical reference points. The second is the use of a set-up margin (SM) that incorporates the uncertainties of patient beam positioning, i.e. systematic and random set-up errors. We propose to replace the random set-up error component of the SM by explicitly incorporating the random set-up error into the dose-calculation model by convolving the incident photon beam fluence with a Gaussian set-up error kernel. This fluence-convolution method was implemented into a Monte Carlo (MC) based treatment-planning system. Also implemented for comparison purposes was a dose-matrix-convolution algorithm similar to that described by Leong (1987 Phys. Med. Biol. 32 327-34). Fluence and dose-matrix-convolution agree in homogeneous media. However, for the heterogeneous phantom calculations, discrepancies of up to 5% in the dose profiles were observed with a 0.4 cm set-up error value. Fluence-convolution mimics reality more closely, as dose perturbations at interfaces are correctly predicted (Wang et al 1999 Med. Phys. 26 2626-34, Sauer 1995 Med. Phys. 22 1685-90). Fluence-convolution effectively decouples the treatment beams from the patient. and more closely resembles the reality of particle fluence distributions for many individual beam-patient set-ups. However, dose-matrix-convolution reduces the random statistical noise in MC calculations. Fluence-convolution can easily be applied to convolution/superposition based dose-calculation algorithms.
منابع مشابه
An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملFLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...
متن کاملCalculations of Linac Photon Dose Distributions in Homogeneous Phantom Using Spline
Introduction Relative dose computation is a necessary step in radiation treatment planning. Therefore, finding an approach that is both fast and accurate seems to be necessary. The purpose of this work was to investigate the feasibility of natural cubic spline to reconstruct dose maps for linear accelerator radiation treatment fields in comparison with those of the simulation. Materials and Met...
متن کاملA dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions.
Treatment verification has been a weak link in external beam radiation therapy. As new and more complicated treatment techniques, such as intensity-modulated radiation therapy (IMRT), are implemented into clinical practice, verifying the accuracy of treatment delivery becomes increasingly important. Existing methods for treatment verification are highly labor intensive. We have developed a meth...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 47 19 شماره
صفحات -
تاریخ انتشار 2002