WE-E-213CD-04: CT to Cone-Beam CT Deformable Registration With Simultaneous Intensity Correction.
نویسندگان
چکیده
PURPOSE To develop and validate a robust CT to cone-beam (CBCT) deformable image registration algorithm that can handle CBCT artifacts and intensity inconsistency, and thus can yield accurate registration results. METHODS We propose a new algorithm called Deformation with Intensity Simultaneously Corrected (DISC). DISC distinguishes itself from the original demons by performing an intensity correction procedure on the CBCT image at every iteration step of demons registration. Specifically, the intensity correction of a voxel in CBCT is achieved by matching the first and the second moments of the image intensities inside a patch around this voxel with those on the CT image. It is expected that such a strategy can remove artifacts in the CBCT image, as well as ensuring the intensity consistency between the two modalities and hence facilitating the registration process. DISC is implemented on computer graphics processing units (GPUs) using the compute unified device architecture (CUDA) programming environment. The performance of DISC has been qualitatively and quantitatively evaluated on a simulated patient case and six head-and- neck cancer patient data. RESULTS Visual inspection shows that original demons distorts the tissues after registration, especially in regions which are heavily degraded by artifacts. DISC, on the other hand, can effectively register CT and CBCT image even in regions contaminated by severe artifacts. The intensity corrected CBCT that extracted from the last iteration of DISC is artifact-free and has similar histogram distribution with the deformed CT. CONCLUSIONS We have developed a robust CT to CBCT deformable image registration method that properly deals with the CBCT artifacts and intensity inconsistency, and thus yields accurate registration results. This work is supported in part by the University of California Lab Fees Research Program, the Master Research Agreement from Varian Medical Systems, Inc., and the grants from the National Natural Science Foundation of China (No.30970866).
منابع مشابه
Joint CT/CBCT deformable registration and CBCT enhancement for cancer radiotherapy
This paper details an algorithm to simultaneously perform registration of computed tomography (CT) and cone-beam computed (CBCT) images, and image enhancement of CBCT. The algorithm employs a viscous fluid model which naturally incorporates two components: a similarity measure for registration and an intensity correction term for image enhancement. Incorporating an intensity correction term imp...
متن کاملHow does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?
PURPOSE To measure the sensitivity of deformable image registration to image noise. Deformable image registration can be used to map organ contours and other treatment planning data from one CT to another. These CT studies can be acquired with either conventional fan-beam CT systems or more novel cone-beam CT techniques. However, cone-beam CT images can have higher noise levels than fan-beam CT...
متن کاملInter-fraction deformable registration of CT and Cone Beam CT images for adaptive radiotherapy
Recent advances in intensity modulated radiotherapy (IMRT) have allowed accurate and fast delivery of treatment dose in the patient. Daily changes in patient geometry need to be accounted for to take full advantage of the increased accuracy of the delivered dose. On-site imaging using cone beam CT and registration of the acquired image with the algorithm presented here provides tools for effici...
متن کاملDemons deformable registration of CT and cone-beam CT using an iterative intensity matching approach.
PURPOSE A method of intensity-based deformable registration of CT and cone-beam CT (CBCT) images is described, in which intensity correction occurs simultaneously within the iterative registration process. The method preserves the speed and simplicity of the popular Demons algorithm while providing robustness and accuracy in the presence of large mismatch between CT and CBCT voxel values ("inte...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 57 21 شماره
صفحات -
تاریخ انتشار 2012