Electron probe microanalysis of Ni-silicides at low voltage: difficulties and possibilities

نویسندگان

  • E. Heikinheimo
  • P. T. Pinard
  • S. Richter
  • X. Llovet
چکیده

Interest in the use of EPMA at low voltage has grown considerably in recent years, mainly because of the availability of electron-beam instruments equipped with field-emission guns. However, EPMA at low voltage is marred by both experimental and analytical problems which may affect the accuracy of quantitative results. In the case of the analysis of transition elements, both the emission and absorption of X-rays are still poorly understood when they originate from electron transitions involving the partially filled 3d-shell. This is the case for the most intense Lα (L3-M5 transition) and Lβ (L2-M4 transition) lines. In this communication, we point out anomalies which appear to afflict the accuracy of EPMA of Ni-silicides using the Ni-Lα X-ray line and we discuss possible solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the composition of Ultra-thin Ni-Si films on Si: constrained modeling of electron probe microanalysis and x-ray reflectivity data

The homogeneous bulk assumption used in traditional electron probe microanalysis (EPMA) can be applied for thin-layered systems with individual layers as thick as 50 nm provided the penetration depth of the lowest accelerating voltage exceeds the total film thickness. Analysis of an NIST Ni-Cr thin film standard on Si using the homogeneous model yielded certified compositions and application of...

متن کامل

In Situ Analysis of Gut Residue of Corophium Volutator (Pallas) by Electron Probe Microanalysis after Exposure to Barytes Spiked Sediments

Corophium volutator (Pallas) has been recommended by the paris Commission as one of the standard species for testing chemical used in offshore oil and gas exploration/production. In the present study, gut contents of Corophium volutator have been analysed by electron probe microanalysis (EPMA) for BaSO4 and other heavy metal impurities after exposure tto spiked sediments followin...

متن کامل

The Use of X-ray Microanalysis in the Study of Diffusion

This paper reviews the use of electron probe microanalysis, scanning electron microscopy and analytical electron microscopy in the measurement of compositional data obtained from diffusion couples. Methods to obtain x—ray spatial resolution as low as mm with the AEM are described. In addition, techniques for improving the detection and for increasing the accuracy of compositional analyses are s...

متن کامل

Barriers to Quantitative Electron Probe X-Ray Microanalysis for Low Voltage Scanning Electron Microscopy

Low voltage x-ray microanalysis, defined as being performed with an incident beam energy ≤5 keV, can achieve spatial resolution, laterally and in depth, of 100 nm or less, depending on the exact selection of beam energy and the composition of the target. The shallow depth of beam penetration, with the consequent short path length for x-ray absorption, and the low overvoltage, the ratio of beam ...

متن کامل

Microwave absorption properties of Ni/(C, silicides) nanocapsules

The microwave absorption properties of Ni/(C, silicides) nanocapsules prepared by an arc discharge method have been studied. The composition and the microstructure of the Ni/(C, silicides) nanocapsules were determined by means of X-ray diffraction, X-ray photoelectric spectroscopy, and transmission electron microscope observations. Silicides, in the forms of SiOx and SiC, mainly exist in the sh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015