The time response function of spark counters and RPCs
نویسندگان
چکیده
The fluctuation theory for the avalanche growth with and without space charge effects is briefly summarized and compared to a broad field of applications. These include spark counters as well as timing and trigger RPCs operated in avalanche mode. A large domain in electrical field strength, pressure, gap size and gas mixture type is covered. A reasonable agreement with the experiment is observed, giving confidence on the validity of both assumptions and treatment of the theory. r 2003 Elsevier B.V. All rights reserved. PACS: 52.80. s; 29.40.Cs; 29.40.Gx
منابع مشابه
Development of high-rate timing RPCs
For many applications of RPCs to time-of-flight counters in heavy ion experiments the expansion to much higher values of the counting rate capability, so far limited to around 2 kHz/cm is of fundamental importance. To address this issue we developed single-gap timing RPCs with resistive electrodes made from a commercially available plastic material. Tests performed in photon beams yielded a tim...
متن کاملResistive plate chambers for time-of-flight measurements
The applications of Resistive Plate Chambers (RPCs) have recently been extended by the development of counters with time resolution below 100 ps s for minimum ionising particles. Applications to HEP experiments have already taken place and many further applications are under study. In this work, we address the operating principles of such counters along with some present challenges, with emphas...
متن کاملOptimization of RFM's Structure Using a New Reformulation of PSO in Case of Limited GCPs
Metaheuristic algorithms have been widely used in determining the optimum rational polynomial coefficients (RPCs). By eliminating a number of unnecessary RPCs, these algorithms increase the accuracy of geometric correction of high-resolution satellite images. To this end, these algorithms use ordinary least squares and a number of ground control points (GCPs) to determine RPCs' values. Due to t...
متن کاملEffect of electrode erosion on the required ignition voltage of spark plug in CNG spark ignition engine
In this article, the electrode erosion and the gap growth of spark plugs were measured on of a CNG fueled engine after durability tests. Then, the required ignition voltage and the spark quality were investigated by a spark plug test rig. Considering results of measurements, the gap growth increased as the running time increased. Thus, the gap growth of spark plugs with 200 and 280 hours runnin...
متن کاملA Test of Planar Spark Counters at the Pep Storage Ring*
A test of planar spark counters (PSC’s.1 at the PEP electron positron storage ring showed the following. PSC’s can be used under harsh experimental conditions without long term degradation of resolution. On line time-of-flight resolutions were &low 200 psec, coordinate resolutions better than 4 mm, both limited to these values by the resistivity of the semi-conducting glass and the electronics ...
متن کامل