Acute and Subacute Toxicity In Vivo of Thermal-Sprayed Silver Containing Hydroxyapatite Coating in Rat Tibia

نویسندگان

  • Masatsugu Tsukamoto
  • Hiroshi Miyamoto
  • Yoshiki Ando
  • Iwao Noda
  • Shuichi Eto
  • Takayuki Akiyama
  • Yutaka Yonekura
  • Motoki Sonohata
  • Masaaki Mawatari
چکیده

To reduce the incidence of implant-associated infection, we previously developed a novel coating technology using hydroxyapatite (HA) containing silver (Ag). This study examined in vivo acute and subacute toxicity associated with the Ag-HA coating in rat tibiae. Ten-week-old rats received implantation of HA-, 2% Ag-HA-, or 50% Ag-HA-coated titanium rods. Concentrations of silver in serum, brain, liver, kidneys, and spleen were measured in the acute phase (2-4 days after treatment) and subacute phase (4-12 weeks after treatment). Biochemical and histological examinations of those organs were also performed. Mean serum silver concentration peaked in the acute phase and then gradually decreased. Mean silver concentrations in all examined organs from the 2% Ag-HA coating groups showed no significant differences compared with the HA coating group. No significant differences in mean levels of glutamic-oxaloacetic transaminase, glutamic-pyruvic transaminase, lactate dehydrogenase, creatinine, or blood urea nitrogen were seen between the three groups and controls. Histological examinations of all organs revealed no abnormal pathologic findings. No acute or subacute toxicity was seen in vivo for 2% Ag-HA coating or HA coating. Ag-HA coatings on implants may represent biologically safe antibacterial biomaterials and may be of value for reducing surgical-site infections related to implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal-sprayed Silver-containing Hydroxyapatite Coating in a Rat Femoral Model: Analysis of the Initial Fixation

Introduction: The degree of osseointegration determines the long-term survival and favorable outcomes of orthopedic implant use. Initial fixation is influenced by a number of factors. Hydroxyapatite (HA) coating has a good osteoconductive property and sealing effect on peri implant migration of particles that lead to osteolysis. Furthermore, HA-coated implants show desirable midterm clinical re...

متن کامل

A Study of Zeta Potential of Plasma Sprayed Hydroxyapatite Coating in Four Simulated Physiological Solutions

The zeta potential magnitude and the duration of its changes have been thought to be directly related to the surface reactivity, the governing of osteoconductivity and availability of valuable information in determining the anticipated in-vivo performance of implants. In this study the zeta potential of plasma sprayed hydroxyapatite (HA) was evaluated in various simulated physiological solution...

متن کامل

Bone Tissue Response to Plasma Sprayed Hydroxyapatite Coatings: An In Vivo Study on Rabbit Femoral Condyles

     In this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. A well-known porous and lamellar microstructure was found in the lateral a...

متن کامل

Acute and Subacute Toxicity of Safranal, a Constituent of Saffron, in Mice and Rats

The acute and sub-acute toxicity of safranal were studied in rat and mice within 2 and 21 days after exposure, respectively. For subacute toxicity, changes in weight as well as biochemical, hematological and pathological parameters were studied. The intraperitoneal LD50 values of safranal were 1.48 mL/kg in male mice, 1.88 mL/kg in female mice and 1.50 mL/kg in male rats. Oral LD50 values were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014