An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation.

نویسندگان

  • Annabel Blasi
  • Joan Beltran
  • Arturo Pereira
  • Graciela Martinez-Palli
  • Abiguei Torrents
  • Jaume Balust
  • Elizabeth Zavala
  • Pilar Taura
  • Juan-Carlos Garcia-Valdecasas
چکیده

BACKGROUND Rotation thromboelastometry (TEM) has been proposed as a convenient alternative to standard coagulation tests in guiding the treatment of coagulopathy during orthotopic liver transplantation (OLT). This study was aimed at assessing the value of TEM in monitoring blood coagulation and guide transfusion support in OLT. STUDY DESIGN AND METHODS Standard coagulation and TEM (EXTEM and FIBTEM) tests were performed at four preestablished intraoperative time points in 236 OLTs and prospectively recorded in a dedicated database together with the main operative and transfusion data. Transfusion thresholds were based on standard coagulation tests. Spearman's rank correlation (ρ), linear regression, and receiver operating characteristic curves were used when appropriate. RESULTS EXTEM maximum clot firmness (MCF(EXTEM)) was the TEM variable that best correlated with the platelet (PLT) and fibrinogen levels (ρ = 0.62 and ρ = 0.69, respectively). MCF(FIBTEM) correlated with fibrinogen level (ρ = 0.70). EXTEM clot amplitude at 10 minutes (A10(EXTEM)) was a good linear predictor of MCF(EXTEM) (R(2) =0.93). The cutoff values that best predicted the transfusion threshold for PLTs and fibrinogen were A10(EXTEM) = 35 mm and A10(FIBTEM) = 8 mm. At these values, the negative and positive predictive accuracies of TEM to predict the transfusion thresholds were 95 and 27%, respectively. CONCLUSION A10(EXTEM) is an adequate TEM variable to guide therapeutic decisions during OLT. Patients with A10(EXTEM) of greater than 35 mm are unlikely to bleed because of coagulation deficiencies, but using A10(EXTEM) of not more than 35 mm as the sole transfusion criterion can lead to unnecessary utilization of PLTs and fibrinogen-rich products.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation.

BACKGROUND Orthotopic liver transplantation can be associated with haemorrhage, particularly in patients with severe liver dysfunction. We assessed the value of rotation thromboelastometry (ROTEM) to monitor coagulation in the operating theatre, its correlation with routine laboratory findings, and its ability to guide platelet (Plt) and fibrinogen (Fg) transfusion. METHODS Twenty-three patie...

متن کامل

Preoperative Thromboelastometry as a Predictor of Transfusion Requirements during Adult Living Donor Liver Transplantation.

BACKGROUND The ability to predict transfusion requirements may improve perioperative bleeding management as an integral part of a patient blood management program. Therefore, the aim of our study was to evaluate preoperative thromboelastometry as a predictor of transfusion requirements for adult living donor liver transplant recipients. METHODS The correlation between preoperative thromboelas...

متن کامل

The role of thromboelastometry in the assessment and treatment of coagulopathy in liver transplant patients

Perioperative monitoring of coagulation is vital to assess bleeding risks, diagnose deficiencies associated with hemorrhage, and guide hemostatic therapy in major surgical procedures, such as liver transplantation. Routine static tests demand long turnaround time and do not assess platelet function; they are determined on plasma at a standard temperature of 37°C; hence these tests are ill-suite...

متن کامل

Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial

BACKGROUND Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patie...

متن کامل

Thromboelastography Use in the Perioperative Transfusion Management of a Patient with Hemophilia A Undergoing Liver Transplantation

The thrombelastogram is a method used to monitor clotting dynamics. Thrombelastography (TE) has been used to guide therapy of coagulation disorders mostly in cardiac surgery but also in liver surgery. TE is a useful tool for perioperative management of patients at risk for coagulopathy. There are several reports describing the use of the thrombelastogram in patients undergoing orthotopic liver ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transfusion

دوره 52 9  شماره 

صفحات  -

تاریخ انتشار 2012