Aggressive granulomatosis after cementless total hip arthroplasty as a result of inflammatory reaction to metal debris: case report.

نویسندگان

  • Bozidar Sebecić
  • Mladen Japjec
  • Bojan Dojcinović
  • Ivonne Zgaljardić
  • Mario Staresinić
چکیده

Massive osteolysis and granulomatous pseudotumor tissue reactions are long-term complications of total hip replacement. It is a condition of localized bone resorption in contact with prosthetic material. It is speculated to be a consequence of metal hypersensitivity or inflammatory reaction to excessive wear. Ten years after total cementless hip replacement (metal on polyethylene surface), a 70-year-old patient presented with hip pain and pseudotumor with massive osteolysis of proximal femur on x-ray. Intraoperatively, extensive metallosis with significantly worn metal head (316L stainless steel) and only slightly worn polyethylene insert was found. Upon extraction, parts of the affected tissue and bone that were in direct contact with the prosthesis were sent for histopathologic analysis. Microscopic examination showed necrotic soft and bone tissue, mainly bone marrow with numerous histiocytes and multinucleated giant cells containing lots of pigmented particles (presumed to be metal particles as a result of implant surface wear). In this case, the primary cause of osteolysis and granulomatosis was inflammatory reaction to metal debris. Aggressive granulomatosis has been first described in cemented prostheses and afterwards also in cementless ones. Conditions such as primary or metastatic neoplastic processes and infection should be excluded. The presence of foreign molecular particles due to wear of the prosthesis by different mediators has been presumed to cause an inflammatory reaction that leads to bone resorption and loosening of the prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Aggressive granulomatous lesions in cementless total hip arthroplasty.

We describe six patients with aggressive granulomatous lesions around cementless total hip prostheses. Two patients previously had a cemented prosthesis in the same hip. The Lord prosthesis was used in five patients, the PCA in one. Both prostheses were made of chrome-cobalt alloy. Pain on weight-bearing occurred on average 3.2 years after the cementless arthroplasty, and at that time radiograp...

متن کامل

Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

BACKGROUND Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentr...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Antibiotic-impregnated Cement Plate for the Treatment of Infected Periprosthetic Femoral Fracture after Cementless Total Hip Arthroplasty - A Case Report -

Copyright c 2012 by Korean Hip Society 245 Periprosthetic femoral fracture is a problematic complication of total hip arthroplasty (THA). Although treatment protocols for periprosthetic femoral fracture have been reported, treatment protocols for periprosthetic fracture with accompanying infection have rarely been published. When these two complications occur together, it becomes more difficult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta clinica Croatica

دوره 52 4  شماره 

صفحات  -

تاریخ انتشار 2013