Preliminary Investigation of Microdosimetric Track Structure Physics Models in Geant4-DNA and RITRACKS
نویسندگان
چکیده
The major differences between the physics models in Geant4-DNA and RITRACKS Monte Carlo packages are investigated. Proton and electron ionisation interactions and electron excitation interactions in water are investigated in the current work. While these packages use similar semiempirical physics models for inelastic cross-sections, the implementation of these models is demonstrated to be significantly different. This is demonstrated in a simple Monte Carlo simulation designed to identify differences in interaction cross-sections.
منابع مشابه
Investigation of the direct DNA damages irradiated by protons of different energies using geant4-DNA toolkit
Background: The total yields of direct Single-Strand Breaks (SSBs) and Double-Strand Breaks (DSBs) in proton energies varying from 0.1 to 40 MeV were calculated. While other studies in this field have not used protons with energy less than 0.5 MeV, our results show interesting and complicated behavior of these protons. Materials and Methods: The simulation has been done using the Geant4-DNA too...
متن کاملA Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy
Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptid...
متن کاملEvaluation of the relative biological effectiveness of the Auger electrons produced during gadolinium neutron capture therapy using microdosimetric approach
Determination of the relative biological effectiveness (RBE) of Auger electrons is a challenging task in radiobiology. In this study, we have estimated the RBE of internal conversion (IC) and Auger electrons released during Gadolinium neutron capture reaction (GNCR) by means of biological weighting functions (BWFs) with microdosimetric approach. Regarding the different distribution of Gadoliniu...
متن کاملAn investigation of neutron direct damages at energies of 0.1-2 MeV on the DNA molecules with atomic structure deduced using Geant4 toolkit
This study proposes a method to estimate RBE of fast neutrons using Monte Carlo simulations. This approach is based on the combination of an atomic resolution DNA geometrical model and Monte Carlo simulations for tracking particles. Atomic positions were extracted from the Protein Data Bank. The GEANT4 code was used for tracking the secondary particles generated by fast neutrons during their in...
متن کاملRadial dose distributions from protons of therapeutic energies calculated with Geant4-DNA.
Models based on the amorphous track structure approximation have been successful in predicting the biological effects of heavy charged particles. Development of such models remains an active area of research that includes applications to hadrontherapy. In such models, the radial distribution of the dose deposited by delta electrons and directly by the particle is the main characteristic of trac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015