Realization of low-loss mirrors with sub-nanometer flatness for future gravitational wave detectors
نویسندگان
چکیده
The second generation of gravitational wave detectors will aim at improving by an order of magnitude their sensitivity versus the present ones (LIGO and VIRGO). These detectors are based on long-baseline Michelson interferometer with high finesse Fabry-Perot cavity in the arms and have strong requirements on the mirrors quality. These large low-loss mirrors (340 mm in diameter, 200 mm thick) must have a near perfect flatness. The coating process shall not add surface figure Zernike terms higher than second order with amplitude >0.5 nm over the central 160 mm diameter. The limits for absorption and scattering losses are respectively 0.5 and 5 ppm. For each cavity the maximum loss budget due to the surface figure error should be smaller than 50 ppm. Moreover the transmission matching between the two inputs mirrors must be better than 99%. We describe the different configurations that were explored in order to respect all these requirements. Coatings are done using IBS. The two first configurations based on a single rotation motion combined or not with uniformity masks allow to obtain coating thickness uniformity around 0.2 % rms on 160 mm diameter. But this is not sufficient to meet all the specifications. A planetary motion completed by masking technique has been studied. With simulated values the loss cavity is below 20 ppm, better than the requirements. First experimental results obtained with the planetary system will be presented. Keyword: Ion beam sputtering, Large Low-losses optics, uniformity, planetary
منابع مشابه
Excess mechanical loss associated with dielectric mirror coatings on test masses in interferometric gravitational wave detectors
Interferometric gravitational wave detectors use mirrors whose substrates are formed from materials of low intrinsic mechanical dissipation. The two most likely choices for the test masses in future advanced detectors are fused silica or sapphire (Rowan S et a1 2000 Plzys. Lett. A 265 5). These test masses must be coated to form minors, highly reflecting at 1064 nm. We have measured the excess ...
متن کاملEvaluation of the performance of polished mirror surfaces for the TAMA gravitational wave detector by use of a wave-front tracing simulation.
We evaluated the performance of polished mirror surfaces for the TAMA interferometric gravitational wave detector by comparing the experimental results with a wave-front tracing simulation. The TAMA mirror surfaces were polished to a roughness of a few nanometer rms. We confirmed that these polished mirrors do not limit the present TAMA sensitivity and that the target shot-noise sensitivity wil...
متن کاملDuality relation between nonspherical mirror optical cavities and its application to gravitational-wave detectors.
In this paper, we analytically prove a unique duality relation between the eigenspectra of paraxial optical cavities with nonspherical mirrors: a one-to-one mapping between eigenmodes and eigenvalues of cavities deviating from flat mirrors by h(r) and cavities deviating from concentric mirrors by -h(r), where h need not be a small perturbation. We then illustrate its application to optical cavi...
متن کاملA Decision between Bayesian and Frequentist Upper Limit in Analyzing Continuous Gravitational Waves
Given the sensitivity of current ground-based Gravitational Wave (GW) detectors, any continuous-wave signal we can realistically expect will be at a level or below the background noise. Hence, any data analysis of detector data will need to rely on statistical techniques to separate the signal from the noise. While with the current sensitivity of our detectors we do not expect to detect any tru...
متن کاملDemonstration of a cavity coupler based on a resonant waveguide grating.
Thermal noise in multilayer optical coatings may not only limit the sensitivity of future gravitational wave detectors in their most sensitive frequency band but is also a major impediment for experiments that aim to reach the standard quantum limit or to cool mechanical systems to their quantum ground state. Here, we present the experimental realization and characterization of a cavity coupler...
متن کامل