Method for gauge block measurement with the heterodyne central fringe identification technique.

نویسندگان

  • Wang-Tsung Wu
  • Yen-Liang Chen
  • Hung-Chih Hsieh
  • Wei-Yao Chang
  • Der-Chin Su
چکیده

In a modified Michelson interferometer, the top face of the wringing platen is first identified using the heterodyne central fringe identification technique. Then the reference mirror located in the other arm is moved by a precision translation stage until the top face of the tested gauge block is also identified with the same technique. The displacement of the mirror is exactly equivalent to the length of the tested gauge block. The measurable range of the interferometer relates to the maximum travel range of the translation stage and its uncertainty depends on the uncertainty of the heterodyne central fringe identification method and the resolution of the translation stage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Electronic Heterodyne Moire Deflectometry and Electroni,; Heterodyne Holographic Interferometry for Flow Measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase object p . Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the intE-ferometric fringe shift. The phase objec...

متن کامل

Absolute height measurement of specular surfaces with modified active fringe reflection deflectometry

Deflectometric methods have existed for more than a decade for slope measurement of specular freeform surfaces through utilization of the deformation of a sample pattern after reflection from a test surface. Usually, these approaches require two-directional fringe patterns to be projected on a LCD screen or ground glass and require slope integration, which leads to some complexity for the whole...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Second-order robust regularization cost function for detecting and reconstructing phase discontinuities.

We propose a robust method for computing discontinuous phase maps from a fringe pattern with carrier frequency. Our algorithm is based on the minimization of an edge-preserving regularized cost function, specifically, on a robust regularized potential that uses a paradigm called the plate with adaptive rest condition, i.e., a second-order edge-preserving potential. Given that the proposed cost ...

متن کامل

به کارگیری روش تداخل سنجی تمام نگاری دیجیتال با نوردهی دوگانه برای محاسبه توزیع دز جذبی در پلیمر پلی متیل متاآکریلات

Double-exposure digital holographic interferometry is a powerful and widespread technique for fine measurement of the induced changes in special physical properties, like density, refractive index and etc. In this paper, application of this technique for measuring the absorbed dose from an electron radiation source in poly (methyl methacrylate) material is studied through modeling. The method o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 49 16  شماره 

صفحات  -

تاریخ انتشار 2010