Dobutamine Tc-99m furifosmin SPECT in detection of coronary artery disease: evaluation of same day, rest-stress protocol.

نویسندگان

  • Bulent Turgut
  • Mustafa Unlu
  • N Hakan Temiz
  • Mehmet T Kitapci
  • Mehmet L Alkan
چکیده

The purpose of this study was to evaluate the feasibility and diagnostic accuracy of same day rest-stress myocardial perfusion SPECT (MP SPECT) protocol by using technetium-99m (Tc-99m) furifosmin in conjunction with dobutamine stress test in subjects in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). The study group consisted of 25 patients (8 female and 17 male with a mean age of 53.04 +/- 8.56 yrs) unable to perform treadmill exercise or unsuitable for pharmacologic vasodilator stress testing. Ten mCi (370 MBq) of Tc-99m furifosmin was injected intravenously at rest. Sixty min after injection, planar and SPECT images were acquired. One hour later all patients underwent dobutamine stress test. At the peak stress, 20 mCi (740 MBq) of Tc-99m furifosmin was injected. Sixty min after stress dose injection, planar and SPECT images were acquired. Rest-stress planar and SPECT data were evaluated by using visual and quantitative analysis. Heart to adjacent organ (Heart/Lung; H/Lu and Heart/Liver; H/Li) activity ratios were calculated from anterior planar images by using regions of interest (ROI). SPECT data were interpreted by using 20 segment-5 point scoring system from short axis and vertical long axis slices. The results of rest-dobutamine stress Tc-99m furifosmin MP SPECT were compared with CA results. There were statistically significant differences between H/Lu and H/Li ratios at rest and stress conditions. Heart/adjacent organ activity ratios were similar and significant statistical difference could not be found between CA positive and CA normal patients. Sensitivity, specificity and accuracy for Tc-99m furifosmin SPECT study were calculated as 90%, 80% and 84% for left anterior descending (LAD), 87%, 94% and 92% for left circumflex (LCx) and 67%, 86% and 80% for right coronary artery (RCA), respectively. Overall sensitivity, specificity and accuracy were calculated as 83%, 87% and 85%, respectively. According to the results obtained in this study, it may be concluded that same day rest-dobutamine stress Tc-99m furifosmin SPECT protocol is a feasible and accurate technique in the evaluation of CAD, especially in patients unable to perform treadmill exercise or unsuitable for pharmacologic vasodilator stress testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dobutamine stress tetrofosmin SPECT; evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease.

OBJECTIVE The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with MIBI SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. METHODS The study group consisted of 19 p...

متن کامل

Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging.

OBJECTIVES The purpose of this study was to determine how frequently and for what reasons the addition of electrocardiographically gated technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) images add value to nongated SPECT perfusion images. BACKGROUND Electrocardiographic gating of Tc-99m sestamibi SPECT images permits assessment of regional and global left ...

متن کامل

Comparative evaluation of the diagnostic accuracy of (99m)Tc-sestamibi gated SPECT using five different sets of image acquisitions at stress and rest phases for the diagnosis of coronary artery disease.

On the basis of some new evidences in favor of delayed (99m)Tc methoxy-isobutyl-isonitrile ((99m)Tc-MIBI) redistribution, doubts about the appropriate time of acquisition following radiotracer injection may be raised. The goal of this study was to find the best acquisition time at stress and rest phases to achieve the highest sensitivity and normalcy rate for (99m)Tc-MIBI SPECT. Ninety four pat...

متن کامل

Comparison of Tl, Tc-Tetrofosmin, and Dobutamine Magnetic Resonance Imaging for Identifying Hibernating Myocardium

Background—Both radionuclide perfusion tracers and contractile response to dobutamine have been used to identify hibernating myocardium. The aim was to compare Tl (thallium) single photon emission CT (SPECT), Tctetrofosmin (tetrofosmin) SPECT, and dobutamine cine MRI for identifying regions of reversible myocardial dysfunction. Methods and Results—Thirty patients with 3-vessel coronary artery d...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2003