Partial-FOV reconstruction in dynamic spiral imaging.

نویسندگان

  • H Sedarat
  • A B Kerr
  • J M Pauly
  • D G Nishimura
چکیده

In many applications of dynamic MR imaging, only a portion of the field-of-view (FOV) exhibits considerable variations in time. In such cases, a prior knowledge of the static part of the image allows a partial-FOV reconstruction of the dynamic section using only a fraction of the raw data. This method of reconstruction generally results in higher temporal resolution, because the scan time for partial-FOV data is shorter. The fidelity of this reconstruction technique depends, among other factors, on the accuracy of the prior information of the static section. This information is usually derived from the reconstructed images at previous time frames. This data, however, is normally corrupted by the motion artifact Because the temporal frequency contents of the motion artifact is very similar to that of the dynamic section, a temporal low-pass filter can efficiently remove this artifact from the static data. The bandwidth of the filter can be obtained from the rate of variations inside and outside the dynamic area. In general, when the temporal bandwidth is not spatially uniform, a bank of low-pass filters can provide a proper suppression of the motion artifact outside the dynamic section. This reconstruction technique is adapted for spiral acquisition and is successfully applied to cardiac fluoroscopy, doubling the temporal resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of undersampled variable density spiral trajectories based on incoherence of spatial aliasing

Introduction: Variable density spiral (VDS) imaging typically samples low spatial frequencies densely and high spatial frequencies sparsely [1]. Reconstructed images are prone to aliasing artifacts, but they are considered to be acceptable in certain cases where aliasing of high spatial frequencies do not significantly deteriorate image quality. VDS imaging is particularly useful for dynamic MR...

متن کامل

Evaluation of the Effect of Tumor Position on Standardized Uptake Value Using Time-of-Flight Reconstruction and Point Spread Function

Objective(s): The present study was conducted to examine whether the standardized uptake value (SUV) may be affected by the spatial position of a lesion in the radial direction on positron emission tomography (PET) images, obtained via two methods based on time-of-flight (TOF) reconstruction and point spread function (PSF). Methods: A cylinder phantom with the sphere (30mm diameter), located in...

متن کامل

23Na SPRITE in vivo Human Brain Tumour Imaging

Introduction Sodium is the most abundant MR-active nucleus in biological tissue after protons. Its very highly regulated concentration in biological tissue, combined with its large variations between healthy and diseased states, make it a very attractive nucleus to image. The development of SPRITE imaging [1] has progressed rapidly in the past few years and much of this work has been driven by ...

متن کامل

A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.

A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode direction allowing an iterative reconstruction using high-resolution phase es...

متن کامل

Filtered-backprojection reconstruction for a cone-beam computed tomography scanner with independent source and detector rotations.

PURPOSE A new cone-beam CT scanner for image-guided radiotherapy (IGRT) can independently rotate the source and the detector along circular trajectories. Existing reconstruction algorithms are not suitable for this scanning geometry. The authors propose and evaluate a three-dimensional (3D) filtered-backprojection reconstruction for this situation. METHODS The source and the detector trajecto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 2000