Evaluation of laminar flow microbiological safety cabinets.
نویسندگان
چکیده
The microbiological control efficiency of two class 100 laminar down-flow hoods was determined by using aerosols of Bacillus subtilis var. niger spores. The first unit challenged utilized a slanted eyelid to partially enclose the front work opening. This hood showed nearly perfect control of ambient organisms in the work area. It also gave a 10(6) or greater drop in the number of organisms passing out of the exhaust system. However, when the interior work area of the hood was challenged, significant numbers of spores penetrated the air barrier and escaped into the ambient air. A redesigned laminar flow hood was built incorporating a vertical eyelid and a reduced opening to the work area. This hood showed the same excellent characteristics for controlling ambient contamination. Exhaust system leakage was also extremely low. Air barrier efficiency for the newer hood was increased with lower amounts of spore penetration into the ambient air.
منابع مشابه
HEPA EXHAUST FILTER IV HEPA SUPPLY FILTER I / All
A microbiological survey of the effectiveness of class II (laminar flow) 'safety' cabinets found in the UK in the last six years is recorded. Only two of the nine units tested approached the containment of aerosols achieved by a good class I (exhaust protective) cabinet. The others were potentially hazardous if used with pathogenic material. The National Sanitation Foundation and the British St...
متن کاملPerformance of exhaust-protective (class I) biological 'safety' cabinets.
Nineteen open-fronted (class I) safety cabinets were subjected to spore containment and airflow tests, which suggested that a flow of 0.75 m/s was the minimum required for safe operation; further tests on three of the cabinets were repeated at different air speeds and confirmed this. The airflow is required to overcome the effect of laboratory or external air currents. Contamination of surfaces...
متن کاملLaboratory contamination of blood cultures.
A prospective study of the use of a laminar flow cabinet, an exhaust-ventilated safety hood, and the open bench for the microbiological examination of blood is described. Blood samples from 1600 patients were subcultured on the open bench, 2700 in a safety hood, and 2607 in a laminar flow cabinet. Use of the laminar flow cabinet produced a significantly greater level of contamination than the o...
متن کاملEvaluation of the Operator Protection Factors Offered by Positive Pressure Air Suits against Airborne Microbiological Challenge
Laboratories throughout the world that perform work with Risk Group 4 Pathogens generally adopt one of two approaches within BSL-4 environments: either the use of positive pressure air-fed suits or using Class III microbiological safety cabinets and isolators for animal work. Within the UK at present, all laboratories working with Risk Group 4 agents adopt the use of Class III microbiological s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 16 10 شماره
صفحات -
تاریخ انتشار 1968