In-Vitro Comparison of Six Continuous Nebulizers*

نویسنده

  • S. David Piper
چکیده

BACKGROUND: Continuous nebulization has become popular for treating patients with severe reversible airway disease. Continuous nebulization therapy has been shown to be safe, effective, and labor efficient as compared to other traditional medication aerosol treatments 1-11 . Although numerous studies have been done evaluating the clinically efficacy of continuous nebulization, little work has been done on comparing the various continuous nebulizers available. In this study, six continuous nebulizers, EZflow, HEART, MiniHEART, UniHEART, IVHEART, and Hope, are evaluated for medication delivered to patient and particle size. METHODS: Each nebulizer was set up and used as described on the product insert accompanying each nebulizer. Each nebulizer was mixed to provide 10 mg/hour of albuterol sulfate based on the nominal output of each nebulizer. Reservoirs were filled to their maximum volume or enough for five hours of nebulization, whichever was less. Airflow was set initially to the nominal airflow specification of the nebulizer and than adjusted incrementally, up or down, until the mean output of the nebulizer, as indicated on the graduations of the nebulizer reservoir, matched the nominal output listed for the nebulizer. Each nebulizer was connected to an aerosol mask as described in the product insert. An inhalation flow of 10 L/ min was simulated; entrained air was humidified. A cascade impactor was used to sample aerosol every hour. Medication delivered and particle size were determined using a spectrophotometer operating at 279 nm. RESULTS: In spite of the fact that each nebulizer was mixed to provide the same amount of medication, there were significant differences in the quantity of medication delivered to the patient. The EZflow Continuous Nebulizer was shown to deliver significantly more medication than the others (p <0.01). The UniHEART and IVHEART delivered the least amount of medication. The HEART had an MMAD of 3.6 microns, which was significantly more than the other nebulizers which had particle sizes ranging from 2.0 to 2.5 microns (p < 0.01). CONCLUSION: Clinically important differences exist between different continuous nebulizers. When comparing the performance of nebulizers it is important to conduct testing under identical conditions which simulate actual clinical use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Six Ultrasound Stimulation Types on Pseudomonas Aeruginosa Growth in Vitro

Background: This work evaluated the efficiency of common ultrasound stimulation (U.S.S) types on bacterial growth in vitro using clinically relevant conditions.Objective: To estimate different frequencies ultrasound bactericidal ability on bacteria in bacteria of Pseudomonas Aeruginosa. Methods: Six types of U.S.S (continuous wave, 7w/cm2, 20 KHz; continuous wave, 35w/0.8L, 40 KHz; continuous ...

متن کامل

Albuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.

OBJECTIVE To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN In vitro, laboratory study. SETTING Research laboratory of a university hospital. INTERVENTIONS Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested ...

متن کامل

In-vitro comparison of 4 large-volume nebulizers in 8 hours of continuous nebulization.

BACKGROUND Continuous albuterol nebulization has become the standard of care for patients with status asthmaticus. Predictable albuterol delivery is paramount for effective therapy. We compared the aerosol characteristics, solution output, and albuterol output of 4 brands of large-volume nebulizer. METHODS We studied 6 units of the following nebulizer brands: AirLife Misty Finity (Cardinal He...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Effects of Six Week Iso-Volume Continuous and Interval Endurance Training on some Inflammatory and Lipid Profiles in Obese and Overweight Soldiers

Background and Aim: Exercise training is known as an anti-inflammatory agent. In this regard, the aim of present study was to investigate the effect of six week iso-volume continuous and interval training on serum levels of IL-18 and CRP and metabolic profile in obese and overweight soldiers. Methods: 28 obese and overweight soldiers chosen as a study subjects and randomly assigned in three gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999