Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report.
نویسندگان
چکیده
We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the time of the latest follow-up. Thirteen hips were associated with noise, and six hips demonstrated fretting of the femoral neck on radiographs. Two hips required a change of the bearings because of a ceramic head fracture. The ten-year survival rate of the alumina-on-alumina total hip prostheses, with revision of any implant for any reason as the end point, was 99.0%. On the basis of those results, we concluded that the rate of survival of primary cementless total hip prostheses with third-generation alumina-on-alumina bearings is excellent at ten years. However, the risk of ceramic fracture, noise, and impingement between the metal neck and the ceramic liner should be a concern to surgeons, and patients should be informed of these risks before surgery.
منابع مشابه
Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. Disappointing experiences with alumina ceramic bearings in the past have led to many improvements in the manufacture and design of ceramic implants. The purpose of the present study was to report the results of contempor...
متن کاملAlternative bearing surfaces in total hip arthroplasty: zirconia-alumina pairing. Contribution or caveat?
The aim of the present study was to evaluate the zirconia and alumina articulation in total hip arthroplasty in regard to clinical and radiological outcome. This is the first report concerning the clinical application of a hybrid ceramic articulation. Owing to ethical reasons, a limited number of patients was enrolled in the study. Ten consecutive patients with degenerative arthritis were rando...
متن کاملLow-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A 17-year follow-up report.
We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no fem...
متن کاملIn vivo wear performance of highly cross-linked polyethylene vs. yttria stabilized zirconia and alumina stabilized zirconia at a mean seven-year follow-up
BACKGROUND Zirconia was introduced as an alternative to alumina for use in the femoral head. The yttria stabilized zirconia material was improved by adding alumina. We evaluated highly cross-linked polyethylene wear performance of zirconia in total hip arthroplasty. The hypothesis was that alumina stabilized zirconia could decrease highly cross-linked polyethylene wear. METHODS Highly cross-l...
متن کاملEffect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina.
We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 92 8 شماره
صفحات -
تاریخ انتشار 2010