Comparison of Keratometric Values Using Javal Keratometer, Oculus Pentacam, and Orbscan II

نویسندگان

  • Hassan Hashemi
  • AbbasAli Yekta
چکیده

Purpose: To compare Orbscan II and Pentacam keratometry readings in terms of their agreement with a manual Javal type keratometer Methods: In this retrospective study, records of patients who had refractive surgery were reviewed. We extracted data of 765 eyes which had keratometry with the Javal keratometer; of these, 577 had Orbscan II and 200 eyes had Pentacam acquisitions. Minimum (min-K) and maximum (max-K) keratometry readings and keratometric astigmatism with the latter two devices were compared with Javal. Results: Correlation coefficients for Javal and Orbscan II in measuring min-K and max-K were r=0.916 and r=0.913, respectively (p<0.001). The 95% limits of agreement (LoA) between Javal and Orbscan II was 1.17-1.20 D for min-K and 1.22-1.24 D for max-K. The coefficients for Pentacam and Javal min-K and max-K readings were very high (r=0.943 and r=0.962). The 95% LoA between Pentacam and Javal in measuring min-K and max-K were 0.51-0.99D and 0.720.99D, respectively. The correlation between Pentacam and Javal measurements of keratometric astigmatism was stronger than that for Orbscan II and Javal (r=0.973 and r=0.800); the 95% LoA was 0.55-0.76D for Pentacam and Javal, and 1.14-1.19D for Orbscan II and Javal. Conclusion: According to this research, Orbscan II and Pentacam had high correlation and agreement with Javal-keratometer in determining keratometric values. Nevertheless, the results obtained from Pentacam showed better agreement and stronger correlation with Javal as compared with Orbscan II. It seems that Pentacam is a suitable substitute for Javal to perform keratometry in normal eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Different Topographic Instruments in Calculating Corneal Power after Myopic Photorefractive Keratectomy

PURPOSE To compare the corneal power measurements obtained using different topographic instruments after myopic photorefractive keratectomy (PRK). METHODS Patients with myopia who were candidates for corneal refractive surgery were sequentially included. Pre-PRK and six months post-PRK corneal powers were measured using Javal manual keratometer, Orbscan II, Galilei, Tomey TMS4, and EyeSys 200...

متن کامل

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

PURPOSE The aim of this study was to determine the agreement between Pentacam HR (Scheimpflug imaging, Oculus) and Orbscan II (scanning slit topography, Bausch and Lomb) in measuring corneal parameters after photorefractive keratectomy (PRK) for hyperopia. METHODS In this prospective cross-sectional study, 38 hyperopic eyes undergoing PRK were examined before refractive surgery and 8 to 10 mo...

متن کامل

Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy

PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...

متن کامل

Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?

PURPOSE To evaluate the accuracy of preoperative keratometers used in cataract surgery with toric intraocular lens (IOL). METHODS Twenty-five eyes received an AcrySof toric IOL implantation. Four different keratometric methods, a manual keratometer, an IOL master, a Pentacam and an auto keratometer, were performed preoperatively in order to evaluate preexisting corneal astigmatism. Difference...

متن کامل

Agreement between Clinical History Method, Orbscan IIz, and Pentacam in Estimating Corneal Power after Myopic Excimer Laser Surgery

The purpose of this study was to investigate the agreement between the clinical history method (CHM), Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was randomly selected by a computer-generated process. At 6 months after surgery, postoperative corneal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014