Refinement of Imaging Processing of Scatter Correction and Beam Hardening Tools for Industrial Radiography and Cone Beam CT
نویسندگان
چکیده
Digital detector arrays are used for industrial radiography and cone beam CT. Scattering and beam hardening artifacts reduce the achievable contrast sensitivity and can severely limit the size of the part to be scanned or require large amounts of shielding to block scatter outside the inspection area of interest. Varian’s image processing toolkit contains a set of dll’s that can easily be deployed to correct radiographs and enhance CT system performance. While this image processing package has been established in the medical area it is not starting to be applied to industrial imaging. Recently, a study was performed on a selection of aluminum industrial parts at 225 kV where computed scatter and beam hardening corrections were shown to improve DR contrast sensitivity and CT number uniformity. In this study, new results are presented based on studies of steel and aluminum parts with 225 kV and 950 kV x-ray sources. Additionally, the effect of a resolution enhancement algorithm (REA) that corrects the light spread from thicker scintillator screens and allows the user to take advantage of higher efficiency screens without sacrificing spatial resolution is evaluated.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملThe Application of Beam Hardening Correction for Industrial X-ray Computed Tomography
X-ray computed tomography (CT) is a non-destructive, radiographic scanning technique that enables the visualisation of both the internal geometry and the composition of a workpiece; X-ray CT is therefore well suited for non-destructive inspection tasks. Several physical processes reduce the quality of CT images, and therefore influence both qualitative and quantitative analyses made from CT dat...
متن کاملIndustrial radiography and tomography based on scanning linear scintillator array
We have developed an industrial CT and Digital Radiography system (CT/DR) for NDT at the USC (Spain). A 510 mm long detector array of 640 detection elements with sub-millimetre spacing (0.8 mm), together with a 50kV mini-focus tube have been integrated in a 3-axis positioning system of flexible configuration. Accurate characterization of geometrical parameters and system commissioning has been ...
متن کاملMega Voltage Cone Beam Computed Tomography (MV- CBCT) using a Standard Medical Linear Accelerator and EPID: A feasibility study.
Introduction: The success of radiotherapy cancer treatment delivery depends on the accuracy of patient positioning for each treatment session. A number of kilovoltage x-ray volumetric imaging modalities with an additional source and detector have been developed to allow patient set-up verification based on the internal anatomy, but a significant portion of medical linacs are on...
متن کاملA Framework for Performance Assessment of Beam Hardening Correction Algorithms in Industrial Computed Tomography
Industrial computed tomography (CT) images often suffer from beam hardening (BH) artefacts. Since beam hardening correction (BHC) is crucial in industrial CT, it is worth acquiring a good understanding of the BHC algorithms. The purpose of this work concerns the development of a phantom-based framework to assess the performance of BHC algorithms in industrial CT, and its application on several ...
متن کامل