Precision of the PRECICE internal bone lengthening nail.
نویسندگان
چکیده
BACKGROUND Previous designs of internal bone lengthening devices have been fraught with imprecise distraction, resulting in nerve injuries, joint contractures, nonunions, and other complications. Recently, a magnet-operated PRECICE nail (Ellipse Technologies, Inc, Irvine, CA, USA) was approved by the FDA; however, its clinical efficacy is unknown. QUESTIONS/PURPOSES We evaluated this nail in terms of (1) accuracy and precision of distraction, (2) effects on bone alignment, (3) effects on adjacent-joint ROM, and (4) frequency of implant-related and non-implant-related complications. METHODS We reviewed medical and radiographic records of 24 patients who underwent femoral and/or tibial lengthening procedures using the PRECICE nail from August 2012 to July 2013 for conditions of varied etiology, the most common being congenital limb length discrepancy, posttraumatic growth arrest, and fracture malunion. This group represented 29% of patients (24 of 82) who underwent a limb lengthening procedure for a similar diagnosis during the review period. At each postoperative visit, the accuracy and precision of distraction, bone alignment, joint ROM, and any complications were recorded by the senior surgeon (SRR). Accuracy reflected how close the measured lengthening was to the prescribed distraction at each postoperative visit, while precision reflected how close the repeated measurements were to each other over the course of total lengthening period. No patients were lost to followup. Minimum followup from surgery was 3 weeks (mean, 14 weeks; range, 3-29 weeks). RESULTS Mean total lengthening was 35 mm (range, 14-65 mm), with an accuracy of 96% and precision of 86%. All patients achieved target lengthening with minimal unintentional effects on bone alignment. The knee and ankle ROM were minimally affected. Of the complications requiring return to the operating room for an additional surgical procedure, there was one (4%) implant failure caused by a nonfunctional distraction mechanism and six (24%) non-implant-related complications, including premature consolidation in one patient (4%), delayed bone healing in two (8%), delayed equinus contracture in two (8%), and toe clawing in one (4%). CONCLUSIONS We conclude that this internal lengthening nail is a valid option to achieve accurate and precise limb lengthening to treat a variety of conditions with limb shortening or length discrepancy. Randomized, larger-sample, long-term studies are required to further confirm clinical efficacy of these devices, monitor for any late failures and complications, and compare with other internal lengthening devices with different mechanisms of operation. LEVEL OF EVIDENCE Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
منابع مشابه
PRECICE magnetically-driven, telescopic, intramedullary lengthening nail: pre-clinical testing and first 30 patients
Introduction: Femoral/tibial lengthening with a telescopic, magnetically-powered, intramedullary nail is an alternative to lengthening with external fixation. Methods: Pre-clinical testing was conducted of the PRECICE in a human cadaver. A retrospective review of the first 30 consecutive patients who underwent unilateral lengthening was also conducted. Nail accuracy was obtained by comparing th...
متن کاملHumerus Lengthening With the PRECICE Internal Lengthening Nail.
BACKGROUND Deformity and growth arrest of the humerus in children may result as sequelae of proximal humerus fractures and unicameral bone cysts, or as complications of their treatment. As approximately 80% of the growth of the humerus arises from the proximal physis, the resultant upper limb-length discrepancy can be substantial. Benefits to lengthening the shortened arm have been previously d...
متن کاملLimb Lengthening Using the PRECICETM Nail System: Complications and Results
BACKGROUND Three types of telescopic nails are mainly used for intramedullary limb lengthening nowadays. Despite some important advantages of this new technology (e.g. controlled distraction rate, not restricted availability, possibility to perform accordion maneuvers), few articles exist on clinical results and complications after lengthening with the PRECICETM nail (Ellipse, USA). OBJECTIVE...
متن کاملLimb Lengthening by Implantable Limb Lengthening Devices
Implantable limb lengthening using noninvasively adjusted telescopic nails dates back to 1983. The newest technology is the Precice (Ellipse Technologies). A retrospective study of the first 65 Precice nails was carried out for the treatment of limb length discrepancy (unilateral) and short stature (bilateral). Successful lengthening was achieved in all patients. There were numerous distraction...
متن کاملLengthening of the humerus with intramedullary lengthening nails—preliminary report
Distraction osteogenesis of the humerus with fully implantable lengthening is now possible since the diameter of the available nails was reduced to 10 mm and below. We report on the first intramedullary lengthening cases of the humerus with two different lengthening devices (FITBONE and PRECICE). Two different approaches and implantation techniques were used. We retrospectively reviewed clinica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 472 12 شماره
صفحات -
تاریخ انتشار 2014