Albuterol metered dose inhaler performance under hyperbaric pressures.

نویسندگان

  • G A Johnson
  • V R Gutti
  • S K Loyalka
  • K A O'Beirne
  • S K Cochran
  • H M Dale
  • G R Kracke
چکیده

The weight change per actuation and aerosol particle size and number delivered by albuterol metered dose inhalers (MDIs) were measured in a multiplace hyperbaric chamber at pressures ranging from one atmosphere absolute (1 ATA, 0 feet of seawater, fsw, 101 kPa) to three ATA (66 fsw, 304 kPa). Weight change per actuation by CFC (chlorofluorocarbon) and long canister HFA (hydrofluoroalkane) powered MDIs was 13 +/- 1% and 12 +/- 1% less, respectively, at 3 ATA compared to 1 ATA. However, weight change per actuation by short canister HFA MDIs was not significantly changed with pressure. The geometric mean diameters of nano particles from the CFC and short canister HFA MDIs decreased from 50 nm at 0 fsw to 32 nm at 66 fsw whereas the long canister HFA aerosol diameters were not affected. The numbers of nanometer size particles delivered at 66 fsw were only 4-7% of those delivered at 0 fsw for the CFC and long canister HFA MDIs whereas for the short canister MDIs it was 26%. We conclude that the weight change per actuation of albuterol and the sizes and numbers of aerosol particles emitted from albuterol MDIs actuated in a hyperbaric environment vary by canister type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of responses to albuterol delivered by two aerosol devices.

Nineteen outpatients with stable obstructive pulmonary disease (mean forced expiratory volume in one second [FEV1], 1.00 + 0.10 L) were evaluated for airway response to albuterol (salbutamol) administered by metered-dose inhaler and Bosch ultrasonic nebulizer (BUSN). Albuterol administered by metered-dose inhaler but not by nebulizer caused a significant increase in FEV1 and the mean forced exp...

متن کامل

Efficiency of Ipratropium Bromide and Albuterol Deposition in the Lung Delivered via a Soft Mist Inhaler or Chlorofluorocarbon Metered‐Dose Inhaler

The propellant-free Combivent Respimat Soft Mist Inhaler (CVT-R) was developed to replace the chlorofluorocarbon-propelled Combivent metered-dose inhaler (CVT-MDI). This steady-state pharmacokinetic (PK) substudy evaluated drug lung-delivery efficiency, using data from two phase III safety and efficacy trials. PK parameters were obtained from well-controlled population PK analyses. Area under t...

متن کامل

Nebulizers vs metered-dose inhalers with spacers for bronchodilator therapy to treat wheezing in children aged 2 to 24 months in a pediatric emergency department.

OBJECTIVE To determine if administration of albuterol by a metered-dose inhaler with a spacer device is as efficacious as administration of albuterol by nebulizer to treat wheezing in children aged 2 years and younger. DESIGN Double-blind, randomized, placebo-controlled clinical trial. SETTING Pediatric emergency department. PATIENTS From a convenience sample of wheezing children aged 2 t...

متن کامل

A comparison between a combination of ipratropium bromide plus fenoterol in a single metered dose inhaler (Duovent) and salbutamol in asthma.

The efficacy of a single metered dose inhaler containing a combination of fenoterol (100 micrograms/puff) and ipratropium bromide (40 micrograms/puff) has been assessed in 12 asthmatics. We conclude that the bronchodilator effect of 2 puffs of the combination inhaler was significantly greater than that achieved by 2 puffs of salbutamol (100 micrograms/puff).

متن کامل

Racial stereotyping: survey of psychiatrists in the United Kingdom.

responses to salbutamol using Diskhaler versus metered-dose inhaler. Comparison of the bronchodilating efficacies of a novel salbutamol metered dose powder inhaler and a pressurised metered dose aerosol with a spacer. Efficacy of a new non-ozone depleting formulation for salbutamol. Comparison of inhaled ter-butaline administered by either the Turbuhaler dry powder or a metered-dose inhaler wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2009