One-point recalibration of heterogeneous enzyme immunoassays with non-linear calibration curves.

نویسندگان

  • H D Meyer
  • H Keller
چکیده

We have investigated one-point recalibration of heterogeneous enzyme immunoassays involving nonlinear calibration curves. By using a factor determined from a single standard we updated calibration curves obtained earlier by means of multiple-point determination. The prerequisite for this method is a reproducible working procedure, i.e., as ensured by a fully mechanized system. In our investigations with Enzymun-Test system ES 600 (Boehringer Mannheim) we determined alpha 1-fetoprotein, carcinoembryonic antigen, digoxin, ferritin, thyroxin-binding globulin, triiodothyronine, and thyroxin in human serum pools over a period of two weeks with both full calibration and one-point recalibration. Comparisons of the results thereby obtained show that the means of the concentrations and the CVs for the alternative calibration procedures differed negligibly, even if we used reagents exposed to different temperatures for different periods of time. With the one-point recalibration procedure presented here, therefore, one can considerably reduce the time and effort spent on calibration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Statistical analysis of the stability of the standard curve for some Syva EMIT assays.

Derivation of standard curves for the EMIT therapeutic drug monitoring system involves several mathematical algorithms, all of which can be rewritten in the form of a linear equation y = mx + b. We examined the stability of the standard curve in terms of slope and y-intercept for three drug assays (procainamide, gentamicin, and carbamazepine) by generating calibration curves intermittently for ...

متن کامل

A multi-allergen standard for the calibration of immunoassays: CREATE principles applied to eight purified allergens.

BACKGROUND Allergen measurements are widely used for environmental exposure assessments and for determining the potency of allergen vaccines, yet few purified allergen standards have been developed. The aim of the study was to develop a single standard containing multiple purified allergens that could be used in enzyme immunoassays and in multiplex arrays for the standardization of allergen mea...

متن کامل

Evaluation of Non- linear Growth Curves Models for Native Slow-growing Khazak Chickens

Native poultry is a valuable genetic source with high resistance against diseases providing an important subject for breeding programs. The non-linear mathematical modeling of the growth pattern may partly explain the relationship between requirements and body weight to precise feeding that plays a vital role in the animal enterprises. A study was conducted to compare five non-linear models inc...

متن کامل

A cautionary note on global recalibration

We report a mathematical result that casts doubt on the possibility of recalibration of probabilities using calibration curves. We then discuss how to interpret this result in the light of behavioral research.

متن کامل

Automated fluorometer/photometer system for homogeneous immunoassays.

A fully automated bench-top clinical analyzer (OPTIMATE TM; Ames/Gilford) performs homogeneous fluorescent immunoassays, colorimetric immunoassays, and determinations of routine blood analytes; drugs, enzymes, metabolites, specific proteins, and hormones in serum. Unique features include a combination fluorescence/absorbance aspirating thermocuvette, a photon-counting fluorometer/photometer, a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 1988