Determination of 3-methoxy-4-hydroxymandelic acid in urine.

نویسندگان

  • J J PISANO
  • J R CROUT
  • D ABRAHAM
چکیده

Five different methods for the determination of 3-methoxy-4-hydroxymandelic acid (vanilmandelic acid, VMA) in urine were compared: a GLC-FID catecholamine metabolite profiling method, an HPLC method with electrochemical detection, the method of Pisano et al. [1962) Clin. Chim. Acta 7, 285-291), a one dimensional paper chromatographic method with diazotized p-nitroaniline staining and the commercially available Bio-Rad VMA by Column Test. The comparison consisted of an imprecision study, a linearity check, a recovery study, a split sample comparison and an interference study. The best results of the imprecision study (n = 8) were found with the Bio-Rad and the HPLC method (within-run imprecision had a coefficient of variation (CV) of 5.1% and 1.4%; between-days CV of 5.9% and 6.0% respectively for values of 32.4 mumol/l and 24.5 mumol/l). The Pisano method had the poorest within-run CV (14.6%) and between-days CV (16.8%) for a value of 23.2 mumol/l. All methods showed good linearity. The mean recovery of the HPLC method was 101.3%; the mean recovery of the other four methods ranged from 93.9%-96.0%. The split sample comparison showed that the accuracy of the HPLC, the GLC and the Pisano method is comparable. The accuracy of the paper chromatographic method and the Bio-Rad method had a positive bias compared with the HPLC method. Especially the positive bias of the Bio-Rad method can be very large. The HPLC method was not influenced by the compounds tested in the interference study, whereas the GLC method in some cases only suffered from overloading problems. The Pisano and the Bio-Rad method were most influenced by the interfering compounds tested. We conclude that the HPLC and the GLC methods are superior to the other three VMA methods. From an analytical point of view HPLC is the method of choice for determining 3-methoxy-4-hydroxymandelic acid in urine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnosis of pheochromocytoma by determination of urinary 3-methoxy-4-hydroxymandelic acid.

In 1957, Armstrong, McMillan and Shaw demonstrated a metabolite of epinephrine (E) and norepinephrine (NE) in normal human urine (2, 3). This substance, 3-methoxy,4-hydroxymandelic acid (VMA, for vanillylmandelic acid), was excreted in abnormally large amounts in three patients with pheochromocytomas (3). Recent studies of sympathomimetic amine metabolism (Figure 1) (4-7) suggested that the uri...

متن کامل

Determination of urinary 3-methoxy-4-hydroxymandelic acid (vanillylmandelic acid) by paper electrophoresis.

called vanillylmandelic acid (VMA), in urine has recently come into use as a confirmatory test for pheochromocytoma (1-6). Armstrong and his associates (1, 2, 7) discovered that this phenolic acid occurred in small amounts in normal human urine and in elevated concentrations in pheochromocytoma. As a result of their observations (1, 2) and especially of those by others in related investigations...

متن کامل

3-methoxy-4-hydroxymandelic acid (vma) by microfiber chromatography.

A method is presented for the rapid, precise, quantitative measurement of 3-methoxy4-hydroxymandelic acid (VMA) in urine. The method is unique in that it utilizes silica-gel-impregnated glass fiber as a support medium for thin-layer chromatography. An ethyl acetate extract of acidified urine was spotted and chromatographed in an ascending technic using tolulene, glacial acetic acid, and ethyl a...

متن کامل

Paper-chromatographic quantitation of 4-hydroxy-3-methoxymandelic acid (VMA) in urine.

We describe a quantitative paperchromatographic method for assaying 3-methoxy-4-hydroxymandelic acid (VMA) in urine. VMA is extracted from acidified urine into ethyl acetate, separated from interfering amine, acid, and alcoholic metabolites by paper chromatography, and reacted with diazotized p-nitroaniline. The colored derivative is eluted and spectrophotometrically analyzed. Recoveries of rep...

متن کامل

Liquid-chromatographic assay for urinary 3-methoxy-4-hydroxymandelic acid, with use of a periodate oxidative monitor.

We describe a "high-performance" liquid-chromatographic procedure for measuring 3-methoxy-4-hydroxymandelic acid (vanillylmandelic acid) in urine. The compound is quantitatively extracted from urine by use of an automated system, including an anion-exchange resin. After elution from the resin and concentration by air drying, the urine extract is chromatographed on an octyl silica column, with u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 1962