Unilateral Headache Status after Intra-Aortic Balloon Pump Placement

نویسندگان

  • Garret M Weber
  • Alan L Gass
  • Shalvi B Parikh
چکیده

INTRODUCTION Intra-aortic balloon pump (IABP) counterpulsation is a catheter-based treatment for coronary artery disease and decompensated heart failure to increase coronary blood flow and improve cardiac output. IABP is generally well tolerated, and complications are usually related to peripheral vasculature or red blood cell and platelet consumption. The usual insertion site via femoral artery renders the patient bedbound. Recently, axillary artery has been used in patients with atherosclerotic peripheral vascular disease and documented small arteries or in those awaiting transplant to ensure ambulation and prevent deconditioning. CASE REPORT We present a patient with ischemic cardiomyopathy and severe left ventricular dysfunction, awaiting Orthotropic Heart Transplant. His worsening intractable angina and dyspnea necessitated IABP placement via left axillary artery, significantly improving his condition. He subsequently experienced migraine-type persistent unilateral headache refractory to standard pain management. Multiple strategies were utilized to treat his pain, but the patient insisted that his pain commenced after IABP placement. Ultimately, the removal of the pump led to complete resolution with no recurrence. CONCLUSION The authors hypothesize that the unilaterally directed blood flow and direct increase in cerebral perfusion from the intra-aortic balloon pump may have caused vasodilation of the extracranial arteries, leading to a persistent and debilitating headache in this susceptible patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Staphylococcus aureus bacteremia associated with intra-aortic balloon pumps.

To the Editor: Since its first clinical use in the late 1960s, intra-aortic balloon pump counterpulsation has been a significant means of supporting an inadequate myocardium.' The use of an intra-aortic balloon pump has increased greatly preceding open heart surgery for cardiogenic shock and left ventricular failure. Additional indications include other conditions such as unstable angina refrac...

متن کامل

A randomized comparison of intra-aortic balloon pumping after primary coronary angioplasty in high risk patients with acute myocardial infarction.

AIMS Intra-aortic balloon pumping reduces afterload and may be effective in improving reperfusion in high risk infarct patients treated with primary angioplasty. METHODS High risk infarct patients referred from other centres for primary PTCA were randomized to treatment with or without an intra-aortic balloon pump. The primary end-point consisted of the combination of death, non-fatal reinfar...

متن کامل

A novel technique for intra-aortic balloon positioning in the intensive care unit.

Proper positioning of the intra-aortic balloon catheter is very important as an improperly placed balloon can cause problems. A balloon placed too high can block off the arch vessels, whereas one placed too low can block the renal and splanchnic vessels. We propose a simple and reliable technique to properly position the intra-aortic balloon pump (IABP) catheter without the use of any sophistic...

متن کامل

Ischemic Colitis Caused by Intra-Aortic Balloon Pump Counterpulsation

Intra-aortic balloon pump counterpulsation (IABP) has been shown to prolong life in critically ill cardiac patients. However, complications including distal emboli, balloon rupture, bleeding, limb loss, and bowel ischemia continue to be associated with them. We present a case of a 56-year-old male who suffered bowel ischemia as a result of a malpositioned IABP. While the benefit of such devices...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017