Designing Of A Smart Transformer
نویسندگان
چکیده
As an integral part of the Smart Grid, smart transformers both work independently to constantly regulate voltage and maintain contact with the smart grid in order to allow remote administration if needed and to provide information and feedback about the power supply and the transformers themselves. Through a process known as voltage optimization, a smart transformer provides the exact amount of power that is needed, and responds instantly to fluctuations within the power grid, acting as a voltage regulator to ensure that the optimized voltage is undisturbed. Because they directly reduce energy consumption, smart transformers therefore directly reduce greenhouse gas emissions as well. As a recognized Smart transformer are a ready and significant source of LEED Points for any business or organization in pursuit of LEED certification. This makes them an important part of any energy retrofit or lighting retrofit. While smart transformers immediately reduce power consumption by providing a stable, optimal power supply that supplies electrical equipment with its ideal voltage, they also protect electrical equipment from power fluctuations – thereby helping electrical equipment last longer. In this paper we discuss on a continuous and discrete smart transformer which is accurate and fast respectively. The continuous smart transformer has a continuous turn ratio and it controls the microgrid side voltage without voltage steps, there for it increases the system accuracy and on another side discrete smart transformer has discrete turn ratio, the output is regulated between several discrete values and discrete smart transformer is less accurate. Index term: smart transformer, microgrid, voltage droop control, on load tap changing transformer, smart transformer control strategies
منابع مشابه
Designing of a New Transformer Ground Differential Relay Based on Probabilistic Neural Network
Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...
متن کاملWind Turbine Transformer Optimum Design Assuming a 3D Wound Core
A wind turbine transformer (WTT) is designed using a 3D wound core while the transformer’s total owning cost (TOC) and its inrush current performance realized as the two objective functions in a multi-objective optimization process. Multi-objective genetic algorithm is utilized to derive Pareto optimal solutions. The effects of inrush current improvement on other operating and design parameters...
متن کاملDesign and Simulation of a 100 kVA Intelligent Universal Transformer Enjoying the Voltage Ratio of 20kv:380v
In order to reduce the volume and size of distribution power transformer, precise and extended controlling of transformer output, the conventional transformers are replaced by intelligent universal transformers (IUTs). In this paper, an IUT, typical of Iran national grid, with the voltage ratio of 20kV:380 V is designed and simulated. Regarding the IUT implementation, a cascaded H-bridge invert...
متن کاملOverload Control in Smart Transformer-Fed Grid
Renewable energy resources and new loads—such as electric vehicles—challenge grid management. Among several scenarios, the smart transformer represents a solution for simultaneously managing lowand medium-voltage grids, providing ancillary services to the distribution grid. However, unlike conventional transformers, the smart transformer has a very limited overload capability, because the junct...
متن کاملPower Auto-transformer Mechanical Faults Diagnosis Using Finite Element based FRA
Frequency response analysis (FRA) is a sensitive method established for testing the mechanical integrity of transformers. However, interpretation of FRA signature still needs expert opinions and there is no FRA interpretation code generally accepted. Various mechanical faults with different extents on power transformers are required to aid FRA interpretation. To address this challenge, in...
متن کامل