Non-fusion procedure using PEEK rod systems for lumbar degenerative diseases: clinical experience with a 2-year follow-up

نویسندگان

  • Weimin Huang
  • Zhengqi Chang
  • Ruoxian Song
  • Ke Zhou
  • Xiuchun Yu
چکیده

BACKGROUND Polyetheretherketone (PEEK) rod system is a novel pedicle-based dynamic stabilization system. This study evaluated clinical and radiographic outcomes of non-fusion surgery by PEEK rod systems for treatment of degenerative lumbar diseases with a 2-year follow-up. METHODS From February 2012 to October 2012, 38 patients who underwent non-fusion surgery using PEEK rod systems were included in the study. Data on Oswestry Disability Index (ODI) score and Japanese Orthopaedics Association (JOA) score were collected and radiographs were obtained to evaluate disc height index (DHI) and range of motion (ROM) at each interval. RESULTS Both JOA and ODI scores significantly improved postoperatively. DHI showed a slight increase immediately after the surgery but gradually dropped below preoperative levels. Mean ROM values changed from 8.8° preoperatively to 1.8° at the 2-year follow-up point. Screw loosening occurred in one case at the 2-year follow-up. CONCLUSIONS The preliminary results indicated a significant improvement in clinical outcomes and advantageous implant safety. The non-fusion procedure using PEEK rod systems might be a viable alternative for treatment of lumbar degenerative diseases. The distraction technique needs to be improved for better postoperative DHI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Posterior spinal fusion using pedicle screws.

Few clinical studies have reported polyetheretherketone (PEEK) rod pedicle screw spinal instrumentation systems (CD-Horizon Legacy PEEK rods; Medtronic, Minneapolis, Minnesota). This article describes a clinical series of 52 patients who underwent posterior spinal fusion using the PEEK Rod System between 2007 and 2010. Of the 52 patients, 25 had degenerative disk disease, 10 had lateral recess ...

متن کامل

Clinical outcomes of two types of cages used in transforaminal lumbar interbody fusion for the treatment of degenerative lumbar diseases: n-HA/PA66 cages versus PEEK cages

This study reports the clinical effects of nano-hydroxyapatite/polyamide66 cages (n-HA/PA66 cages) and compares the clinical outcomes between n-HA/PA66 and polyetheretherketone cages (PEEK cages) for application in transforaminal lumbar interbody fusion (TLIF). A retrospective and case-control study involving 124 patients using n-HA/PA66 cages and 142 patients using PEEK cages was conducted. Al...

متن کامل

The SNAP trial: a double blind multi-center randomized controlled trial of a silicon nitride versus a PEEK cage in transforaminal lumbar interbody fusion in patients with symptomatic degenerative lumbar disc disorders: study protocol

BACKGROUND Polyetheretherketone (PEEK) cages have been widely used in the treatment of lumbar degenerative disc disorders, and show good clinical results. Still, complications such as subsidence and migration of the cage are frequently seen. A lack of osteointegration and fibrous tissues surrounding PEEK cages are held responsible. Ceramic implants made of silicon nitride show better biocompati...

متن کامل

Polyetheretherketone (PEEK) Rods in Lumbar Spine Degenerative Disease: A Case Series.

STUDY DESIGN Retrospective case series. OBJECTIVE The purpose of our study was to retrospectively review the results of posterior lumbar fusion using polyetheretherketone (PEEK) rods. SUMMARY OF BACKGROUND DATA Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the lumbar spine for degenerative disease. Rigid fixation with tit...

متن کامل

Flexible Stabilisation of the Degenerative Lumbar Spine Using PEEK Rods.

Posterior lumbar interbody fusion using cages, titanium rods, and pedicle screws is considered today as the gold standard of surgical treatment of lumbar degenerative disease and has produced satisfying long-term fusion rates. However this rigid material could change the physiological distribution of load at the instrumental and adjacent segments, a main cause of implant failure and adjacent se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016