Signal Quality in Dry Electrode EEG and the Relation to Skin-electrode Contact Impedance Magnitude
نویسندگان
چکیده
Current EEG research approaches are focusing on developing new dry electrode EEG (electroencephalogram) systems providing a high enough signal quality for a wide range of applications. This study proposes several parameters for evaluating signal quality of dry electrodes and relates the results to skin-electrode contact impedance magnitude values. The EEG recordings of a Ag/AgCl pinned electrode and a flexible polymer pinned electrode are evaluated through a comparison to conductive gel electrode recordings. The experimental setup was made up of two EEG acquisition systems connected in parallel. The protocol included open eyes, closed eyes and steady-state visually evoked potentials (SSVEP) sessions in both seated and walking in place conditions. The parameters used for evaluation were signal correlations, signal coherence and signal-to-noise ratios (SNRs). Results showed that the three proposed parameters provided equivalent outcome for signal quality estimation for the same recordings. There was no relation reported between the defined signal quality and the skin-electrode contact impedance in either dry or gel electrodes, although high impedance variations were present among subjects. However, larger impedance magnitude and impedance magnitude variations, and lower signal quality is observed for dry electrodes compared to gel ones.
منابع مشابه
Comparative Results of Simultaneous Evoked Response Potential Measurements Using Dry Contact Electrodes and Conventional Wet Electrodes
Abstract Practical sensing of biopotentials such as the electroencephalogram (EEG) in operational settings has been severely limited by the need for skin preparation and conductive electrolytes at the skin-sensor interface. Another seldom-noted problem has been the need for a low impedance connection from the body to ground for cancellation of common-mode noise voltages. In this article we desc...
متن کاملScalp electrode impedance, infection risk, and EEG data quality.
OBJECTIVES Breaking the skin when applying scalp electroencephalographic (EEG) electrodes creates the risk of infection from blood-born pathogens such as HIV, Hepatitis-C, and Creutzfeldt-Jacob Disease. Modern engineering principles suggest that excellent EEG signals can be collected with high scalp impedance ( approximately 40 kOmega) without scalp abrasion. The present study was designed to e...
متن کاملA dry electrode for EEG recording.
This paper describes the design, fabrication and testing of a prototype dry surface electrode for EEG signal recording. The new dry electrode has the advantages of no need for skin preparation or conductive paste, potential for reduced sensitivity to motion artifacts and an enhanced signal-to-noise ratio. The electrode's sensing element is a 3 mm stainless steel disk which has a 2000 A (200 nm)...
متن کاملDry and noncontact EEG sensors for mobile brain-computer interfaces.
Dry and noncontact electroencephalographic (EEG) electrodes, which do not require gel or even direct scalp coupling, have been considered as an enabler of practical, real-world, brain-computer interface (BCI) platforms. This study compares wet electrodes to dry and through hair, noncontact electrodes within a steady state visual evoked potential (SSVEP) BCI paradigm. The construction of a dry c...
متن کاملSoft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Conventional gel electrodes are widely used for biopotential measurements, despite important drawbacks such as skin irritation, long set-up time and uncomfortable removal. Recently introduced dry electrodes with rigid metal pins overcome most of these problems; however, their rigidity causes discomfort and pain. This paper presents dry electrodes offering high user comfort, since they are fabri...
متن کامل