Bioabsorbable miniplating versus metallic fixation for metacarpal fractures.
نویسندگان
چکیده
Bioabsorbable implants offer an attractive alternative to metallic implants to stabilize small bone fractures in the hand. Self-reinforced bioabsorbable miniplating for metacarpal fractures was studied in bones from cadavers and compared with standard metallic fixation methods. One hundred twelve fresh-frozen metacarpals from humans had three-point bending and torsional loading after transverse osteotomy followed by fixation using seven methods: (1) dorsal and (2) dorsolateral 2-mm self-reinforced polylactide-polyglycolide 80/20 plating, (3) dorsal and (4) dorsolateral 2-mm self-reinforced poly-L/DL-lactide 70/30 plating, (5) dorsal 1.7-mm titanium plating, (6) dorsal 2.3-mm titanium plating, and (7) crossed 1.25-mm Kirschner wires. In apex dorsal and palmar bending, dorsal self-reinforced polylactide-polyglycolide and poly-L/DL-lactide plates provided stability comparable with dorsal titanium 1.7-mm plating. When the bioabsorbable plates were applied dorsolaterally, apex palmar rigidity was increased and apex dorsal rigidity was decreased. Bioabsorbable platings resulted in higher torsional rigidity than 1.7-mm titanium plating and in failure torque comparable with 2.3-mm titanium plating. Low-profile selfreinforced polylactide-polyglycolide and poly-L/DL-lactide miniplates provide satisfactory biomechanical stability for metacarpal fixation. These findings suggest that bioabsorbable miniplating can be used safely in the clinical stabilization of metacarpal and phalangeal fractures.
منابع مشابه
Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.
Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided ...
متن کاملForeign-Body Granuloma after Metacarpal Fracture Treatment with Absorbable Implants
The treatment of unstable fractures or complex injuries of the hand frequently requires the implementation of rigid internal fixation. Traditionally, metallic implants have been used to achieve stability. However, the complication rates of metallic implants are high, with major complications reported in 36% of the patients considered in a series [1]. These complications included nonunion, delay...
متن کاملMetacarpal Fractures
The majority of metacarpal fractures are closed injuries amenable to conservative treatment with external immobilization and subsequent rehabilitation. Internal fixation is favored for unstable fracture patterns and patients who require early motion. Percutaneous pinning usually is successful for metacarpal neck fractures and comminuted head fractures. Shaft and base fractures can be treated wi...
متن کاملSurgical Fixation of Fourth and Fifth Metacarpal Shaft Fractures with Flexible Intramedullary Absorbable Rods: Early Clinical Outcomes and Implications.
BACKGROUND To avoid the irritation of tendons and soft tissues as well as hardware-related problems, we designed an intramedullary fixation with bioabsorbable rods for the treatment of the metacarpal shaft fractures. METHODS Five patients with nine shaft fractures of the fourth and fifth metacarpi were treated with intramedullary absorbable implants and followed up with an average of 4.2 mont...
متن کاملLocking Plate Alone versus in Combination with Two Crossed Kirschner Wires for Fifth Metacarpal Neck Fracture
Fracture of fifth metacarpal neck commonly requires open reduction and internal fixation. However, the current methods of internal fixation in fifth metacarpal neck fractures remain unsatisfactory. Patients with fractures of fifth metacarpal neck received open reduction and internal fixation with either locking plate in combination with two crossed Kirschner wires (K-wires) or locking plate alo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 410 شماره
صفحات -
تاریخ انتشار 2003