Quantitative Ethylene Measurements with MOx Chemiresistive Sensors at Different Relative Air Humidities
نویسندگان
چکیده
The sensitivity of two commercial metal oxide (MOx) sensors to ethylene is tested at different relative humidities. One sensor (MiCS-5914) is based on tungsten oxide, the other (MQ-3) on tin oxide. Both sensors were found to be sensitive to ethylene concentrations down to 10 ppm. Both sensors have significant response times; however, the tungsten sensor is the faster one. Sensor models are developed that predict the concentration of ethylene given the sensor output and the relative humidity. The MQ-3 sensor model achieves an accuracy of ±9.2 ppm and the MiCS-5914 sensor model predicts concentration to ±7.0 ppm. Both sensors are more accurate for concentrations below 50 ppm, achieving ±6.7 ppm (MQ-3) and 5.7 ppm (MiCS-5914).
منابع مشابه
Self-Test Procedures for Gas Sensors Embedded in Microreactor Systems
Metal oxide (MOX) gas sensors sensitively respond to a wide variety of combustible, explosive and poisonous gases. However, due to the lack of a built-in self-test capability, MOX gas sensors have not yet been able to penetrate safety-critical applications. In the present work we report on gas sensing experiments performed on MOX gas sensors embedded in ceramic micro-reaction chambers. With the...
متن کاملData set from chemical sensor array exposed to turbulent gas mixtures
A chemical detection platform composed of 8 chemo-resistive gas sensors was exposed to turbulent gas mixtures generated naturally in a wind tunnel. The acquired time series of the sensors are provided. The experimental setup was designed to test gas sensors in realistic environments. Traditionally, chemical detection systems based on chemo-resistive sensors include a gas chamber to control the ...
متن کاملInvestigation of Pristine Graphite Oxide as Room-Temperature Chemiresistive Ammonia Gas Sensing Material
Graphite oxide has been investigated as a possible room-temperature chemiresistive sensor of ammonia in a gas phase. Graphite oxide was synthesized from high purity graphite using the modified Hummers method. The graphite oxide sample was investigated using scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, thermogravimetry and differential scanning calorimet...
متن کاملExploratory data analysis for industrial safety application
We tested the detection properties of four MOX sensors toward different ozone mixtures to identify sets of sensing layers and interfering compounds concentrations most suitable for a reliable detection of ozone. The measurement campaign lasted 1 year divided in four sessions. We collected a substantial amount of measurements (more than 500) with diverse interfering gases: ammonia, ethanol, ethy...
متن کاملCarbon Nanotube-Based Chemiresistive Sensors
The development of simple and low-cost chemical sensors is critically important for improving human life. Many types of chemical sensors have been developed. Among them, the chemiresistive sensors receive particular attention because of their simple structure, the ease of high precise measurement and the low cost. This review mainly focuses on carbon nanotube (CNT)-based chemiresistive sensors....
متن کامل