Biological treatment and thickening with a hollow fibre membrane bioreactor.
نویسندگان
چکیده
Aerobic operation of an immersed hollow fibre membrane bioreactor, treating municipal wastewater supplemented with molasses solution, has been studied across mixed liquor suspended solids (MLSS) concentrations between 8 and 32 g L(-1), the higher concentrations being normally associated with thickening operations. Only a marginal loss in membrane permeability was noted between 8 and 18 g L(-1) when operation was conducted without clogging. The sustainable operational flux attainable above 18 g L(-1) was highly dependent upon both the MLSS concentration and the state of the membrane. A temperature-corrected flux of 28 L m(-2) h(-1) (LMH) was sustained for 18 h at an MLSS of 8 g L(-1) using membranes close to initial their virgin-state permeability. This value decreased to around 14 LMH at 20 g L(-1) and 5 LMH at 32 g L(-1) MLSS for an aged membrane whose permeability had been recovered following clogging. Below the threshold flux operation without significant clogging was possible, such that the membrane permeability could be recovered with a chemically enhanced backflush (CEB). Above this flux clogging took place at a rate of around 7-14 g solids per m(2) membrane per m(3) permeate volume passed irrespective of the MLSS concentration. The permeability of the unclogged membrane was depressed and could not be recovered using a standard CEB, indicative of irrecoverable pore clogging. The outcomes corroborated previously reported observations concerning the deleterious long-term impacts of clogging, and confirmed the critical importance of operation at a sustainable flux value.
منابع مشابه
Municipal Wastewater Treatment Using a Hollow Fiber Membrane Bioreactor
A bioreactor equipped with hollow fiber microfiltration membranes was applied for wastewater treatment. Removal of chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) was investigated. The experimental setup consisted of influent and effluent tanks, and membrane modules using Polyvinyl Di–Fluoride (PVDF) hollow fibers. The operation program included suction and backwash...
متن کاملEvaluating the Sintering Temperature Control Towards the Adsorptivity of Ammonia onto the Natural Zeolite Based Hollow Fibre Ceramic Membrane
The disproportionate quantity of ammonia presence in water has led to serious drinkable water scarcity worldwide. The abundant source of mineral and superior cations selectivity has made natural zeolite as a good adsorbent for the ammonia removal. This work aims to fabricate natural zeolite based hollow fibre ceramic membrane (HFCM) via extrusion based phase inversion and sintering techniques f...
متن کاملBiological treatment of mixtures of toluene and n-hexane vapours in a hollow fibre membrane bioreactor.
Membrane bioreactors are gaining interest for the control of contaminated air streams. In this study, the removal of toluene and n-hexane vapours in a hollow fibre membrane bioreactor (HFMB) was investigated. The focus was on quantifying the possible interactions occurring during the simultaneous biotreatment of the two volatile pollutants. Two lab-scale units fitted with microporous polypropyl...
متن کاملEfficient treatment of baker’s yeast wastewater using aerobic membrane bioreactor
A membrane bioreactor (MBR) system based on a dead-end immersed hollow fiber membrane and filamentous fungus Aspergillus oryzae were used for treatment of baker’s yeast wastewater. The fungus was adapted to the wastewater in the bioreactor for two weeks before starting the continuous process. Average organic loading rate of 4.2 kg COD/m3.d was entered the bioreactor. MBR system was able to redu...
متن کاملHollow Fiber Membrane Bioreactor for COD Biodegradation of Tapioca Wastewater
The present work studied the application of membrane bioreactor (MBR) for tapioca wastewater processing that contained chemical oxygen demand (COD) ranging from 4000-9000 mg/L. A preliminary study was initially conducted in order to evaluate membrane performance with respect to its flux with MLSS concentration ranging from 4,500 to 10,500 mg/L. It was clear that fouling was observed during the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water research
دوره 58 شماره
صفحات -
تاریخ انتشار 2014