OBJECTIVE To prospectively measure accuracy, reliability, and image quality of telemedical retinopathy of prematurity (ROP) diagnosis. METHODS Two-hundred forty-eight eyes from 67 consecutive infants underwent wide-angle retinal imaging by a trained neonatal nurse at 31 to 33 weeks' and/or 35 to 37 weeks' postmenstrual age (PMA) using a standard protocol. Data were uploaded to a Web-based telemedicine system and interpreted by 3 expert retinal specialist graders who provided a diagnosis (no ROP, mild ROP, type 2 prethreshold ROP, treatment-requiring ROP) and an evaluation of image quality for each eye. Findings were compared with a reference standard of indirect ophthalmoscopy by an experienced pediatric ophthalmologist. RESULTS At 35 to 37 weeks' PMA, sensitivity and specificity for diagnosis of mild or worse ROP were 0.908 and 1.000 for grader A, 0.971 and 1.000 for grader B, and 0.908 and 0.977 for grader C. Sensitivity and specificity for diagnosis of type 2 prethreshold or worse ROP were 1.000 and 0.943 for grader A, 1.000 and 0.930 for grader B, and 1.000 and 0.851 for grader C. At 35 to 37 weeks' PMA, weighted kappa for intergrader reliability was 0.791 to 0.889, and kappa for intragrader reliability for detection of type 2 prethreshold or worse ROP was 0.769 to 1.000. Image technical quality was rated as "adequate" or "possibly adequate" for diagnosis in 93.3% to 100% of eyes. CONCLUSION A telemedicine system using nurse-captured retinal images has the potential to improve existing shortcomings of ROP management, particularly at later PMAs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Image-Based Technology: Impact of Referral Cutoff on Accuracy and Reliability of Remote Retinopathy of Prematurity Diagnosis

Telemedicine has potential to improve the delivery, quality, and accessibility of ophthalmic care for infants with Retinopathy of Prematurity (ROP). Using a telemedicine screening strategy, three potential diagnostic cutoffs may be used to define disease that warrants ophthalmologic referral: presence of any ROP, presence of moderate ("type-2 prethreshold") ROP, or presence of severe ROP requir...

متن کامل

Macular hole formation without vitreofoveal traction.

on the eye increases intraocular pressure to approximately 90 mm Hg, which is sufficient to overcome systolic pressures and cease central retinal artery blood flow. Given that even hard squeeze blinks have been shown to increase intraocular pressure in a range from 50 to 110 mm Hg, it is certainly conceivable that the appearance of peripheral ROP in this patient may have been altered through th...

متن کامل

[Reliability of retinal imaging screening in retinopathy of prematurity].

INTRODUCTION The retinopathy of prematurity (ROP) is a potentially avoidable cause of blindness in children. The advances in neonatal care make the survival of extremely premature infants, who show a greater incidence of the disease, possible. The aim of the study is to evaluate the reliability of ROP screening using retinography imaging with the RetCam 3 wide-angle camera and also study the va...

متن کامل

Computer-Assisted Digital Image Analysis of Plus Disease in Retinopathy of Prematurity.

The objective of this study is to review the current state and role of computer-assisted analysis in diagnosis of plus disease in retinopathy of prematurity. Diagnosis and documentation of retinopathy of prematurity are increasingly being supplemented by digital imaging. The incorporation of computer-aided techniques has the potential to add valuable information and standardization regarding th...

متن کامل

Diagnosis of plus disease in retinopathy of prematurity using Retinal Image multiScale Analysis.

PURPOSE To evaluate a semiautomated image analysis software package, Retinal Image multiScale Analysis (RISA), for the diagnosis of plus disease in preterm infants with retinopathy of prematurity (ROP). METHODS Digital images of the posterior pole showing both disc and macula in preterm infants with ROP were analyzed with an enhanced version of RISA. Venules (N = 106) and arterioles (N = 44) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 125 11  شماره 

صفحات  -

تاریخ انتشار 2007