Percutaneous lung biopsy with a fine bore cutting needle (Vacu-Cut): improved results using drill technique.

نویسنده

  • N Milman
چکیده

BACKGROUND Percutaneous transthoracic needle biopsy is used in the diagnosis of pulmonary and pleural lesions. The standard procedure using the Vacu-Cut cutting type of needle is the "thrust" technique in which the needle is rapidly forced through the lesion. In our experience this technique has a low yield of histological biopsy specimens. The diagnostic yield of a new biopsy technique ("drill" technique) using the Vacu-Cut needle was assessed. METHODS The series comprised 29 consecutive patients, 23 with localised peripheral pulmonary lesions and six with pleural lesions. The Vacu-Cut 1.2 mm needle was rotated and drilled by hand through the lesion. RESULTS Biopsy specimens 4-30 mm long were obtained in 20 of the 23 patients with pulmonary lesions; in three patients material was available for cytological examination only. The diagnostic yield in the 18 malignant pulmonary lesions was 89% and in the five non-malignant lesions 80%. Biopsy specimens 10-30 mm long were obtained in all patients with pleural lesions. The diagnostic yield in the four malignant and two non-malignant lesions was 100%. The total diagnostic yield in malignant lesions was 20 of 22 patients and in non-malignant lesions six of seven patients. The diagnostic yield in the entire series was 26 of 29 patients (90%). Pneumothorax occurred in seven of the patients and three needed a chest tube. There was no haemoptysis and no deaths. CONCLUSIONS The drill technique has a high diagnostic yield in both malignant and non-malignant pulmonary and pleural lesions, and is suggested as the ideal biopsy technique when using the Vacu-Cut needle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...

متن کامل

CT-guided biopsy of lung lesions: defining the best needle option for a specific diagnosis

OBJECTIVES To evaluate the performance of fine and cutting needles in computed tomography guided-biopsy of lung lesions suspicious for malignancy and to determine which technique is the best option for a specific diagnosis. METHODS This retrospective study reviewed the data from 362 (71.6%) patients who underwent fine-needle aspiration biopsy and from 97 (19.7%) patients who underwent cutting...

متن کامل

Percutaneous needle biopsy of the mediastinum: review of 94 procedures.

BACKGROUND A number of reports of radiologically guided percutaneous biopsy of mediastinal masses have been described but techniques have varied, particularly the type of needle used. In this study mediastinal biopsies with fine aspiration needles and cutting needles have been compared, sometimes in the same patient. The results are reviewed with particular emphasis on the choice of biopsy need...

متن کامل

Ultrasound guided percutaneous cutting biopsy for the diagnosis of pulmonary consolidations of unknown aetiology.

BACKGROUND Ultrasound has been used to guide percutaneous aspiration biopsy of thoracic tumours with high diagnostic yield. This study assessed the diagnostic value of ultrasound guided percutaneous cutting biopsy for pulmonary consolidation of unknown aetiology. METHODS Thirty patients with undiagnosed lobar or segmental consolidation underwent ultrasound guided percutaneous needle aspiratio...

متن کامل

Percutaneous trephine biopsy of the lung.

Needle lung biopsy performed with a trephine cutting needle attached to a high speed pneumatic drill is a new technique which can be expected to yield a high quality lung specimen in 85 percent 90 percent of attempts. This technique is especially applicable to diffuse pulmonary disease. The most frequent complication is the development of pneumothorax (in up to 65 percent of biopsies) which if ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 1995