QASCI-Quadruple Asymmetric Saddles for Cardiac Imaging

نویسندگان

  • M. B. Snyder
  • P. H. Chan
  • F. Robb
چکیده

Introduction: The existing cardiac coil in the market is an 8-channel coil with 4 anterior loops and four posterior loops with a fieldof-view coverage of 30 cm by 30 cm. One finds that the clinical demand for cardiac coils is split into two segments: one is those coils which are solely for cardiac imaging with a field-of-view requirement of 30 cm by 30 cm to cover the heart only; the other segment is for cardiovascular imaging with a field-of-view requirement of 48 cm by 48 cm in order to be capable of performing vascular imaging. In order to increase channel count, element size must be restricted, which limits the coil’s penetration depth, and thus sensitivity to deep tissues. In addition, most high channel cardiac imaging coil systems are both heavy and bulky, making them difficult for the technician/operator to use, and cause the patient discomfort. Therefore a need exists to create a cardiac/cardiovascular imaging coil system that is lightweight, simple to use, and which offers excellent imaging performance throughout the thoracic region. In this study we have constructed a 32-channel phased array MRI coil system designed specifically for cardiac and thoracic vascular imaging. What makes the coil unique and unlike prior art is the specific combination of geometric elements within the design. A new array motif design, the QASQI (Quadruple Asymmetric Saddle for Cardiac Imaging), is used to generate those elements closest to the cardiac region, where they comprise a total of 16 channels (or half of the total channels) of the overall design (Fig 1). To aid patient comfort, the eight rectangular loops can be detached from the QASCI core when cardiac-only imaging is needed, thus decreasing the weight of the system. Thus, an integrated design approach is taken to realize a user-friendly system that is highly optimized for clinical cardiac imaging use. Methods and Materials: The methods consisted of hardware development, modeling and data measurement. Hardware Development: When two groups of QASCI elements are combined with eight rectangular-loop elements, the overall design of the present coil is realized (Fig 1). The peripheral loops provide the depth-of-penetration needed to view deep vasculature, while the four QASCI elements provide a relatively shallow but very high SNR/resolution image of the heart itself. With this combination of elements, it is possible to view the entirety of the thorax, but the FOV has been optimized specifically to meet the needs of cardiac and vascular imaging. Data Measurement: Phantom testing for each topology was done using 1.5T GE Excite scanner and a sequence (TR/TE = ms/ms; 256*128; FOV = 44cm) and a SOS reconstruction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy window setting for optimum Tl-201 cardiac imaging [Persian]

  Introduction: Poor sensitivity and poor signal to noise ratio because of low injected thallium dose and presence of scattered photons are the main problems in using thallium in scintigraphic imaging of the heart. Scattered photons are the main cause of degrading the contrast and resolution in SPECT imaging that result in error in quantification. Thallium decay is ve...

متن کامل

Exact image reconstruction for triple-source cone-beam CT along saddle trajectories

In this paper, we propose an exact shift-invariant filtered backprojection (FBP) algorithm for triple-source saddle-curve cone-beam CT. In this imaging geometry, the sources are symmetrically positioned along a circle, and the trajectory of each x-ray source is a saddle. Then, we extend Yang’s formula from the single-source case to the triple-source case. The saddles can be divided into four pa...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Evaluation of Cardiac Mitochondrial Function by a Nuclear Imaging Technique using Technetium-99m-MIBI Uptake Kinetics

Mitochondria play an important role in energy production for the cell. The proper function of a myocardial cell largely depends on the functional capacity of the mitochondria.  Therefore it is necessary to establish a novel and reliable method for a non-invasive assessment of mitochondrial function and metabolism in humans. Although originally designed for evaluating myocardial perfusion, 99mTc...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009