Costs of remote monitoring vs. ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study

نویسندگان

  • Laurence Guédon-Moreau
  • Dominique Lacroix
  • Nicolas Sadoul
  • Jacques Clémenty
  • Claude Kouakam
  • Jean-Sylvain Hermida
  • Etienne Aliot
  • Salem Kacet
چکیده

AIMS The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). METHODS AND RESULTS The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were seen once a year unless the system reported an event mandating an ambulatory visit, while patients in the control group were seen in the ambulatory department every 6 months. The costs of each follow-up strategy were compared, using the actual billing documents issued by the French health insurance system, including costs of (i) (a) ICD-related ambulatory visits and transportation, (b) other ambulatory visits, (c) cardiovascular treatments and procedures, and (ii) hospitalizations for the management of cardiovascular events. The ICD and RM system costs were calculated on the basis of the device remaining longevity at the end of the study. The characteristics of the study groups were similar. Over a follow-up of 27 months, the mean non-hospital costs per patient-year were €1695 ± 1131 in the active, vs. €1952 ± 1023 in the control group (P = 0.04), a €257 difference mainly due to device management. The hospitalization costs per patient-year were €2829 ± 6382 and €3549 ± 9714 in the active and control groups, respectively (P = 0.46). Adding the ICD to the non-hospital costs, the savings were €494 (P = 0.005) or, when the monitoring system was included, €315 (P = 0.05) per patient-year. CONCLUSION From the French health insurance perspective, the remote management of ICD patients is cost saving. CLINICAL TRIALS REGISTRATION NCT00989417, www.clinicaltrials.gov.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial

AIMS The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS The trial's primary objective was to randomly compare the proportions of patients experiencing ≥ 1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related ...

متن کامل

Patient perspective on remote monitoring of cardiovascular implantable electronic devices: rationale and design of the REMOTE-CIED study

BACKGROUND Remote patient monitoring is a safe and effective alternative for the in-clinic follow-up of patients with cardiovascular implantable electronic devices (CIEDs). However, evidence on the patient perspective on remote monitoring is scarce and inconsistent. OBJECTIVES The primary objective of the REMOTE-CIED study is to evaluate the influence of remote patient monitoring versus in-cl...

متن کامل

Quarterly vs. yearly clinical follow-up of remotely monitored recipients of prophylactic implantable cardioverter-defibrillators: results of the REFORM trial

AIMS The rapidly increasing number of patients with implantable cardioverter-defibrillators (ICD) places a large burden on follow-up providers. This study investigated the possibility of longer in-office follow-up intervals in primary prevention ICD patients under remote monitoring with automatic daily data transmissions from the implant memory. METHODS AND RESULTS Conducted in 155 ICD recipi...

متن کامل

The benefits of remote monitoring in long-term care for patients with implantable cardioverter-defibrillators.

OBJECTIVE The increasing number of patients with implantable cardiac devices raises the need for more efficient outpatient follow-up care. Due to technological progress in communication and transmission systems and in the implantable devices themselves, telemonitoring can be widely used as an important part of care for patients and devices. Our objective was to evaluate the benefits of continuo...

متن کامل

Current clinical evidence for remote patient management.

Pacemaker (PM) and implantable cardioverter defibrillator (ICD) patients are ideally suited to remote management in the form of remote follow-up as well as of remote monitoring, which are both acts of telemedicine. Large randomized trials, such as TRUST, COMPAS, CONNECT, ECOST and EVOLVO, and the huge ALTITUDE registry provided a high level of evidence for the multiple advantages of remote mana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014