Behavior of entropy/complexity measures of the electroencephalogram during propofol-induced sedation: dose-dependent effects of remifentanil.

نویسندگان

  • Rain Ferenets
  • Ann Vanluchene
  • Tarmo Lipping
  • Björn Heyse
  • Michel M R F Struys
چکیده

BACKGROUND Several new measures based on the regularity of the electroencephalogram signal for the assessment of depth of anesthesia/sedation have been proposed recently. In this study we analyze the influence of remifentanil and electroencephalogram frequency content of the performance of a set of such measures. METHODS Forty-five patients with American Society of Anesthesiologists physical status I were randomly allocated to one of three groups according to the received dose of predicted effect compartment-controlled remifentanil (0, 2, and 4 ng/ml). All 45 patients received stepwise increased effect site concentration-controlled dose of propofol. At every step of propofol increase, the Observer's Assessment of Alertness/Sedation score was assessed. The following measures were calculated from the electroencephalographic signal: spectral entropy, approximate entropy, Higuchi fractal dimension, Lempel-Ziv complexity, relative beta ratio, and SyncFastSlow measure. RESULTS The behavior of the electroencephalogram-based measures is highly sensitive to the frequency content of the signal and the dose of remifentanil. The prediction probability with respect to the Observer's Assessment of Alertness/Sedation score of the most discriminative measure, the Higuchi fractal dimension, dropped from 0.90 (electroencephalographic frequency band 6-47 Hz, no remifentanil) to 0.55 when the frequency band was changed to 0.5-19 Hz and to 0.83 when remifentanil concentration was increased to 4 ng/ml. The coeffect of remifentanil on electroencephalographic regularity is bimodal depending on the frequency band of the signal. CONCLUSIONS Cutting off high frequencies from the electroencephalogram and increased remifentanil concentration deteriorate the performance of the electroencephalogram-based entropy/complexity measures as indicators of the depth of propofol sedation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sedative and Analgesic efficacy of Propofol-Ketamine and Propofol-Remifentanil During Painful Procedures in Children with Acute Lymphoblastic Leukemia

Background: Lumbar puncture (LP) and bone marrow aspiration or biopsy in pediatric patients with hematological diseases is often repeated at regular intervals. These procedures are painful and unpleasant and bring a lot of stress for the children and their families. This study aimed to compare the effectiveness of two drug combinations of propofol-ketamine and propofol-remifentanil in children ...

متن کامل

مقایسه اثرات سداتیو رمیفنتانیل با پروپوفول در اعمال جراحی کاتاراکت سالمندان تحت بلوک موضعی رترو بولبار

Background: Because general anesthesia is not a good choice in elderly ASA>II patients candidate for cataract surgery performored by ophthalmology Residents and lack of cooperation in these patients, sedative effect and hemodynamic status and side effects of two drugs, Remifentanil & propofol  are compared.   Methods : In a Randomized clinical trial on 60 patients candidate for cataract su...

متن کامل

A Comparative Study of Remifentanil/Propofol versus Alfentanil/Propofol for Wake-up Test in Major Spinal Surgery

Background: Early warning of potential damage to spinal cord during major spinal surgery is highly desirable to prevent post-operative neurological deficits. Wake-up test is a simple, safe and reliable method of recognition of such a complication, and has been extensively used in many spinal surgical units. The present study is evaluating the remifentanil, propofol versus alfentanil, propofol a...

متن کامل

Assessment of Nociceptive Responsiveness Levels during Sedation-Analgesia by Entropy Analysis of EEG "2279

The level of sedation in patients undergoing medical procedures is decided to assure unconsciousness and prevent pain. The monitors of depth of anesthesia, based on the analysis of the electroencephalogram (EEG), have been progressively introduced into the daily practice to provide additional information about the state of the patient. However, the quantification of analgesia still remains an o...

متن کامل

Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index.

BACKGROUND We compared two spectral entropies, state entropy (SE) and response entropy (RE), based on the irregularity of the EEG, to measure loss of response to verbal command (LOR(verbal)) and noxious stimulus (LOR(noxious)) with the bispectral index (BIS) during propofol infusion with and without remifentanil. METHODS Three groups of 20 patients received an effect-site controlled propofol ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 106 4  شماره 

صفحات  -

تاریخ انتشار 2007