Comparison of intraocular lens decentration and tilt measurements using 2 Purkinje meter systems.

نویسندگان

  • Sophie Maedel
  • Nino Hirnschall
  • Natascha Bayer
  • Sabine Markovic
  • Juan Tabernero
  • Pablo Artal
  • Frank Schaeffel
  • Oliver Findl
چکیده

PURPOSE To evaluate the difference in intraocular lens tilt and decentration measurements with 2 Purkinje meters. SETTING Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. DESIGN Prospective evaluation of diagnostic test. METHODS This single-center study included pseudophakic patients in 2 substudies in which 3 consecutive measurements were performed with 2 Purkinje meters (Spanish and German). In substudy 1, an inexperienced examiner performed all measurements after a short learning period. In substudy 2, all measurements were taken by experienced examiners under direct supervision of the inventors of the devices. RESULTS Substudy 1 included 53 pseudophakic eyes in which all 53 scans were successful with the Spanish device; however, only 35 measurements (66%) were successful with the German Purkinje meter. The mean tilt measured with the Spanish Purkinje meter was 4.35 degrees ± 2.50 (SD) and 9.20 ± 6.96 degrees with the German Purkinje meter. The mean decentration was 0.44 ± 0.19 mm and 0.74 ± 0.91 mm, (P = .44), respectively. In substudy 2 (29 pseudophakic eyes), the number of successful scans was 29 (100%) and 18 (62%) for the Spanish meter and German Purkinje meter, respectively. The mean horizontal and vertical tilt difference vector between the 2 systems was 4.89 ± 3.24 degrees and 7.57 ± 3.82 degrees, respectively. CONCLUSIONS Concerning clinical feasibility, the Spanish Purkinje meter had a greater percentage of successful scans than the German device. In addition, this device measured significantly higher tilt values than the Spanish Purkinje meter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular lens tilt and decentration measurements: Purkinje imaging versus Scheimpflug imaging

Purpose: To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems. Methods: Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus) and custom algorithms, and a custom-built Purkinje imaging apparatus. Both methods were validated with a physical model eye where tilt and decentration can b...

متن کامل

Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...

متن کامل

Impact of intraocular lens haptic design and orientation on decentration and tilt.

PURPOSE To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter. SETTING Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. DESIGN Randomized pilot study with intrapatient comparison. METHODS In part 1 of this study, patients received plate-haptic IOL...

متن کامل

Phakometry and lens tilt and decentration using a custom-developed Purkinje imaging apparatus: validation and measurements.

We present a Purkinje imaging system for phakometry and measurement of tilt and decentration of crystalline and intraocular lenses (IOLs). Crystalline lens radii of curvature were estimated by using both a merit function and the equivalent mirror approaches. Tilts and decentrations were estimated by using Phillips's linear analysis. We present a complete validation of the technique through exha...

متن کامل

Intraocular lens alignment from purkinje and Scheimpflug imaging.

The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 43 5  شماره 

صفحات  -

تاریخ انتشار 2017