Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
نویسندگان
چکیده
OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were examined for the occurrence of right ventricular failure. Right ventricular failure was defined as requiring a right ventricular assist device, 14 or more days of inotropic support after implantation, and/or inotropic support starting more than 14 days after implantation. Demographics, along with clinical, laboratory, and hemodynamic data, were compared between patients with and without right ventricular failure, and risk factors were identified. RESULTS Overall, 30 (6%) patients receiving left ventricular assist devices required a right ventricular assist device, 35 (7%) required extended inotropes, and 33 (7%) required late inotropes. A significantly greater percentage of patients without right ventricular failure survived to transplantation, recovery, or ongoing device support at 180 days compared with patients with right ventricular failure (89% vs 71%, P < .001). Multivariate analysis revealed that a central venous pressure/pulmonary capillary wedge pressure ratio of greater than 0.63 (odds ratio, 2.3; 95% confidence interval, 1.2-4.3; P = .009), need for preoperative ventilator support (odds ratio, 5.5; 95% confidence interval, 2.3-13.2; P < .001), and blood urea nitrogen level of greater than 39 mg/dL (odds ratio, 2.1; 95% confidence interval, 1.1-4.1; P = .02) were independent predictors of right ventricular failure after left ventricular assist device implantation. CONCLUSIONS The incidence of right ventricular failure in patients with a HeartMate II ventricular assist device is comparable or less than that of patients with pulsatile-flow devices. Its occurrence is associated with worse outcomes than seen in patients without right ventricular failure. Patients at risk for right ventricular failure might benefit from preoperative optimization of right heart function or planned biventricular support.
منابع مشابه
Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.
BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...
متن کاملEditorial comment: Adverse events in long-term ventricular assist device therapy.
the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...
متن کاملSurvival after left ventricular assist device with and without temporary right ventricular support.
BACKGROUND Right ventricular (RV) failure after the insertion of a left ventricular assist device (LVAD) historically results in poor outcomes. Patients requiring temporary RV support after LVAD insertion are a heterogeneous group of patients consisting of those in cardiogenic shock after myocardial infarction, to those with chronic decompensated heart failure. For patients requiring biventricu...
متن کاملApical pseudoaneurysm following continuous flow left ventricular assist device placement.
The HeartMate II continuous flow left ventricular assist device (LVAD) (Thoratec Inc) provides circulatory support for patients with medically refractory systolic heart failure as both a bridge to transplantation and destination therapy. Although left ventricular apical pseudoaneurysm has rarely been reported with first-generation pulsatile flow LVADs, this has not been previously reported with...
متن کاملEffects of the HeartMate II continuous-flow left ventricular assist device on right ventricular function.
BACKGROUND Continuous-flow devices have become the standard of care for mechanical circulatory support for end-stage heart failure patients because of improved survival and durability. The effects of these devices, such as the HeartMate II (HMII) left ventricular assist device (LVAD), on right ventricular (RV) function have not been evaluated in detail. This study evaluated the incidence of RV ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of thoracic and cardiovascular surgery
دوره 139 5 شماره
صفحات -
تاریخ انتشار 2010