Objective Evaluation of the Prosthesis Diameter on Hearing Results after Stapedotomy

نویسندگان

  • Erkan Karatas
  • Hale Cam Deniz
چکیده

stapedotomy. Materials and Methods: The diameters of prostheses used were 0.3 mm and 0.6 mm in two groups of ten patients. and 10 healthy patients as control group were included. Transient evoked otoacoustic emissions (TEOAE), Distortion product otoacoustic emissions (DPOAE) and DPOAE I/O functions were recorded. Results: Significant changes were detected at 2000-3000 Hz (p<0.001) and 4000-6000 Hz (p<0.05) for 0.6 mm prostheses in TEOAE statistically. Also 3000-4000 Hz for 0.6 mm prostheses (p<0.05) for DPOAE and with 65 dB at 2000 Hz (p<0.05), with 60 dB and 45 dB at 3000 Hz (p<0.05) for DPOAE I/O were found statictically. Conclusions: OAE measurements are advisable for follow-up examinations in otosclerosis patients with stapedotomy. An increase in prosthesis diameter for stapedotomy gives better hearing results, not only at lower frequencies, but also at higher.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hearing results after stapedotomy with a nitinol piston prosthesis.

OBJECTIVE To compare the hearing results in patients with otosclerosis who underwent a stapedotomy with either a platinum wire prosthesis or a commercially available, heat-activated nitinol stapes piston prosthesis. DESIGN Retrospective medical chart review. SETTING Academic tertiary care medical center. PATIENTS Seventy-nine consecutive patients diagnosed as having otosclerosis who under...

متن کامل

Audiometric evaluation after stapedotomy with Fisch titanium prosthesis.

UNLABELLED Otosclerosis causes the fixation of the stapes and conductive hearing loss, usually corrected with the use of hearing aids or through stapedotomy and the replacement of the involved stapes with a prosthesis. Titanium has been the most recently used material of choice in stapedotomy prostheses. Only two prostheses are commercially available in Brazil. There are no reports in the liter...

متن کامل

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

Hearing and Otoacoustic Emissions Outcome of Stapedotomy: Does the Prosthesis Diameter Matter?

OBJECTIVE To compare the hearing and otoacoustic emissions (OAE) outcome of stapedotomy employing 0.4 and 0.6 mm diameter prostheses. MATERIALS AND METHODS In total, 18 patients with otosclerosis participated in a prospective, double-armed, randomized cohort study. All the patients underwent small fenestra drill stapedotomy employing the Causse fluroplastic large loop piston prostheses. The p...

متن کامل

Comparison of the Effectiveness of teflon piston and titanium stapes prosthesis in hearing improvement

Background & objectives: The aim of this study was to compare the effectiveness of two stapes prostheses in hearing improvement of patients undergoing stapes surgery for otosclerosis.   Materials & Methods: In this retrospective and descriptive study, the charts of 291 stapedectomies performed by one surgeon (first author) from 1997 to 2011 in Imam Khomeini and Apadana hospitals of Ahvaz were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -