Comparative analysis of SmartArc‐based dual arc volumetric‐modulated arc radiotherapy (VMAT) versus intensity‐modulated radiotherapy (IMRT) for nasopharyngeal carcinoma
نویسندگان
چکیده
The purpose of this study was to evaluate and quantify the planning performance of SmartArc-based volumetric-modulated arc radiotherapy (VMAT) versus fixed-beam intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC) using a sequential mode treatment plan. The plan quality and performance of dual arc-VMAT (DA-VMAT) using the Pinnacle3 Smart-Arc system (clinical version 9.0; Philips, Fitchburg, WI, USA) were evaluated and compared with those of seven-field (7F)-IMRT in 18 consecutive NPC patients. Analysis parameters included the conformity index (CI) and homogeneity index (HI) for the planning target volume (PTV), maximum and mean dose, normal tissue complication probability (NTCP) for the specified organs at risk (OARs), and comprehensive quality index (CQI) for an overall evaluation in the 11 OARs. Treatment delivery time, monitor units per fraction (MU/fr), and Gamma(3 mm, 3%) evaluations were also analyzed. DA-VMAT achieved similar target coverage and slightly better homogeneity than conventional 7F-IMRT with a similar CI and HI. NTCP values were only significantly lower in the left parotid gland (for xerostomia) for DA-VMAT plans. The mean value of CQI at 0.98 ± 0.02 indicated a 2% benefit in sparing OARs by DA-VMAT. The MU/fr used and average delivery times appeared to show improved efficiencies in DA-VMAT. Each technique demonstrated high accuracy in dose delivery in terms of a high-quality assurance (QA) passing rate (> 98%) of the Gamma(3 mm, 3%) criterion. The major difference between DA-VMAT and 7F-IMRT using a sequential mode for treating NPC cases appears to be improved efficiency, resulting in a faster delivery time and the use of fewer MU/fr.
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملA Hybrid IMRT/VMAT Technique for the Treatment of Nasopharyngeal Cancer
Hybrid IMRT/VMAT technique which combined intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) was developed for the treatment of nasopharyngeal cancer (NPC). Two-full-arc VMAT (2ARC-VMAT), 9-field IMRT (9F-IMRT), and Hybrid IMRT/VMAT plans for NPC were compared in terms of the dosimetric quality, sparing of organs at risk (OARs), and delivery efficiency. The Hybr...
متن کاملDosimetric Comparison between Single and Dual Arc-Volumetric Modulated Arc Radiotherapy and Intensity Modulated Radiotherapy for Nasopharyngeal Carcinoma Using a Simultaneous Integrated Boost Technique
Backround: Plan quality and performance of dual arc (DA) volumetric modulated arc therapy (VMAT) , single arc (SA) VMAT and nine field (9F) intensity modulated radiotherapy were compared using a simultaneous integrated boost (SIB) technique. Methods: Twelve patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with SA/DA-VMAT using a CMS Monaco Treatment Planning System ...
متن کاملA bias‐free, automated planning tool for technique comparison in radiotherapy ‐ application to nasopharyngeal carcinoma treatments
In this study a novel, user-independent automated planning technique was developed to objectively compare volumetric modulated arc therapy (VMAT) and intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma planning, and to determine which technique offers a greater benefit for parotid-sparing and dose escalation strategies. Ten patients were investigated, with a standard prescripti...
متن کاملWhich T Category of Nasopharyngeal Carcinoma May Benefit Most from Volumetric Modulated Arc Therapy Compared with Step and Shoot Intensity Modulated Radiation Therapy
BACKGROUND To compare volumetric modulated arc therapy (VMAT) with conventional step and shoot intensity modulated radiation therapy (s-IMRT) in nasopharyngeal carcinoma (NPC) patients, and identify which T category patient gains the maximum benefit from VMAT. METHODS Fifty-two patients that randomly selected from 205 patients received VMAT at a single center were retrospectively replanned wi...
متن کامل