Field Survey on Human Thermal Comfort Reports in Air-Conditioned Offices in Taiwan
نویسندگان
چکیده
Field experiments, conducted in 29 air-conditioned offices, used survey questionnaires and physical measurements to investigate workers’ subjective thermal responses and comfort perception. A total of 650 individuals participated in the field study. The thermal neutrality and thermal preference of subjects occurred at 25.6°C and 24.1°C respectively. Responses from those subjects suggest a comfort temperature range is 23.8–27.5oC, that shifts to slightly warmer temperatures by about 0.5oC as comparing to comfort zone recommended in ASHRAE standard 55. Responses from subjects also indicate that people in Taiwan have a leniency toward the humidity guideline in ASHRAE standard 55, due to acclimate to the humid climate. The findings were compared with the similar studies in hot-humid climate.
منابع مشابه
Thermal Comfort in Offices – Natural Ventilation vs. Air Conditioning
Based on both subjective and objective data, a study was carried out in order to identify differences in the perception of thermal comfort of office workers in naturally ventilated and air-conditioned buildings. The analysis of the interviews shows that occupants of naturally ventilated office buildings are significantly more satisfied with their thermal environment than occupants in air-condit...
متن کاملInvestigation of combined effects of noise and low air temperature on human-environmental comfort and physiological responses- An experimental study
Background and Aim: Combined exposure to noise and temperature can affect the neurophysiological responses of the office staff. The present study was done to investigate the impacts of combined exposure to noise and low air temperature on physiological responses and environmental comfort. Methods: In this experimental study, the studied population included the students who were randomly selecte...
متن کاملImplementation of adaptive indoor comfort temperature control via embedded system for air-conditioning unit
Environmental control strategy via computerized implementation is one of the most efficient approaches to integrate new advanced knowledge in research of human thermal comfort to a mechanical air-conditioning unit. Recently, a new conceptual development in designing air-conditioning systems has indicated that the indoor comfort temperature strongly depends upon changes of the outdoor air temper...
متن کاملAssessment of productivity loss in air-conditioned buildings using PMV index
This theoretical study reports on the assessment of productivity loss in air-conditioned office buildings using the PMVapproach and makes use of Wyon’s reviews [D.P. Wyon, P.O. Fanger, B.W. Olesen, C.J.K. Pedersen, The mental performance of subjects clothed for comfort at two different air temperatures, Ergonomics 18 (1975) 358–374; D.P. Wyon, Individual microclimate control: required range, pr...
متن کاملTimber Chips as the Insulation Material for Energy Saving in Prefabricated Offices
This research demonstrates the feasibility of a roof insulation method for prefabricated offices that uses vinyl packed timber chips to reduce air conditioning loads (hereinafter referred to as AC loads) and which also improves indoor thermal comfort. The advantages of the new roof insulation method were revealed through comparing the impacts of four roof types on prefabricated offices. The AC ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007